TY - JOUR
T1 - Development of a cathartic-free colorectal cancer screening test using virtual colonoscopy
T2 - a feasibility study.
AU - Johnson, Kristina T.
AU - Carston, Michael J.
AU - Wentz, Robert J.
AU - Manduca, Armando
AU - Anderson, Steven M.
AU - Johnson, C. Daniel
PY - 2007/1
Y1 - 2007/1
N2 - OBJECTIVE: The purpose of our study was to develop a method to subtract barium-labeled stool from the colon using a phantom and to evaluate the performance of the technique in a pilot human population. MATERIALS AND METHODS: A phantom containing 6-mm flat polyps and three types of simulated stool (homogeneous, moderately heterogeneous, and severely heterogeneous) mixed with barium was created, scanned, and tested using three stool subtraction algorithms but no cathartic. Thirty patients with suspected colorectal polyps were studied using stool tagging to determine which was the most effective stool subtraction algorithm. Colonoscopy was the reference standard. Examinations were evaluated blindly using the unsubtracted and 6 weeks later both the unsubtracted and subtracted data sets. RESULTS: A threshold of 200 H and expansion and convolution techniques were the most effective tools for subtracting stool and minimizing artifacts. When applied to the human population, sensitivities using the unsubtracted data sets were 90% (18/20) and 68% (26/38) for polyps > or = 1 cm and > or = 5 mm, respectively. Specificities were 100% (4/4) and 75% (3/4) for polyps > or = 1 cm and > or = 5 mm. For the stool-subtracted data sets, sensitivities were 90% (18/20) and 71% (27/38) for polyps > or = 1 cm and > or = 5 mm. Per patient sensitivities were 88% (15/17) and 77% (20/26) for > or = 1 cm and > or = 5 mm polyps. Specificities were 100% (4/4) for large polyps and 25% (1/4) for smaller polyps. CONCLUSION: Image processing tools combining thresholding, expansion, and convolution were the most useful for stool subtraction. Laxative-free colon examinations using barium for stool labeling can be performed at CT colonography with or without stool subtraction with high accuracy. Further study is warranted.
AB - OBJECTIVE: The purpose of our study was to develop a method to subtract barium-labeled stool from the colon using a phantom and to evaluate the performance of the technique in a pilot human population. MATERIALS AND METHODS: A phantom containing 6-mm flat polyps and three types of simulated stool (homogeneous, moderately heterogeneous, and severely heterogeneous) mixed with barium was created, scanned, and tested using three stool subtraction algorithms but no cathartic. Thirty patients with suspected colorectal polyps were studied using stool tagging to determine which was the most effective stool subtraction algorithm. Colonoscopy was the reference standard. Examinations were evaluated blindly using the unsubtracted and 6 weeks later both the unsubtracted and subtracted data sets. RESULTS: A threshold of 200 H and expansion and convolution techniques were the most effective tools for subtracting stool and minimizing artifacts. When applied to the human population, sensitivities using the unsubtracted data sets were 90% (18/20) and 68% (26/38) for polyps > or = 1 cm and > or = 5 mm, respectively. Specificities were 100% (4/4) and 75% (3/4) for polyps > or = 1 cm and > or = 5 mm. For the stool-subtracted data sets, sensitivities were 90% (18/20) and 71% (27/38) for polyps > or = 1 cm and > or = 5 mm. Per patient sensitivities were 88% (15/17) and 77% (20/26) for > or = 1 cm and > or = 5 mm polyps. Specificities were 100% (4/4) for large polyps and 25% (1/4) for smaller polyps. CONCLUSION: Image processing tools combining thresholding, expansion, and convolution were the most useful for stool subtraction. Laxative-free colon examinations using barium for stool labeling can be performed at CT colonography with or without stool subtraction with high accuracy. Further study is warranted.
UR - http://www.scopus.com/inward/record.url?scp=34249940340&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34249940340&partnerID=8YFLogxK
U2 - 10.2214/AJR.05.1484
DO - 10.2214/AJR.05.1484
M3 - Article
C2 - 17179324
AN - SCOPUS:34249940340
SN - 0361-803X
VL - 188
SP - W29-36
JO - The American journal of roentgenology and radium therapy
JF - The American journal of roentgenology and radium therapy
IS - 1
ER -