Detrending phase drift: A preprocessing step to improve the effectiveness of the UNFOLD technique

Yanle Hu

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Purpose: To improve the effectiveness of the UNFOLD technique in removing aliasing artifacts by detrending temporal phase drift in each voxel before the implementation of the UNFOLD technique. This is because linear and quadratic phase trends in temporal signal can shift and broaden aliasing peaks in the spectrum and cause the removal of aliasing artifacts by spectral filtering to be insufficient or even fail when minimal filtering of the spectrum is used. Materials and Methods: A functional magnetic resonance imaging (fMRI) study with a visual stimulus was performed on normal subjects to test the hypothesis. A 2D spiral-in/out sequence was used to acquire k-space data. Undersampled k-space trajectories were used to improve temporal resolution. Aliasing artifacts were removed by the UNFOLD technique. For comparison, two image sets, with and without phase trends removal, were obtained from each set of functional data. Results: After detrending temporal phase drift, residual aliasing artifacts that were not suppressed by the standard UNFOLD technique could be successfully removed. Better image quality, temporal stability, and activation maps could be achieved by the proposed method. Conclusion: The proposed method can improve the effectiveness of the UNFOLD technique in removing aliasing artifacts when spectral filtering is kept minimal to preserve temporal resolution.

Original languageEnglish (US)
Pages (from-to)742-747
Number of pages6
JournalJournal of Magnetic Resonance Imaging
Volume33
Issue number3
DOIs
StatePublished - Mar 2011
Externally publishedYes

Fingerprint

Artifacts
Magnetic Resonance Imaging

Keywords

  • Aliasing artifacts
  • Bold fMRI
  • Phase trend removal
  • Spiral
  • UNFOLD

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Detrending phase drift : A preprocessing step to improve the effectiveness of the UNFOLD technique. / Hu, Yanle.

In: Journal of Magnetic Resonance Imaging, Vol. 33, No. 3, 03.2011, p. 742-747.

Research output: Contribution to journalArticle

@article{7614813b6a8045e4a87b4e8dda246caa,
title = "Detrending phase drift: A preprocessing step to improve the effectiveness of the UNFOLD technique",
abstract = "Purpose: To improve the effectiveness of the UNFOLD technique in removing aliasing artifacts by detrending temporal phase drift in each voxel before the implementation of the UNFOLD technique. This is because linear and quadratic phase trends in temporal signal can shift and broaden aliasing peaks in the spectrum and cause the removal of aliasing artifacts by spectral filtering to be insufficient or even fail when minimal filtering of the spectrum is used. Materials and Methods: A functional magnetic resonance imaging (fMRI) study with a visual stimulus was performed on normal subjects to test the hypothesis. A 2D spiral-in/out sequence was used to acquire k-space data. Undersampled k-space trajectories were used to improve temporal resolution. Aliasing artifacts were removed by the UNFOLD technique. For comparison, two image sets, with and without phase trends removal, were obtained from each set of functional data. Results: After detrending temporal phase drift, residual aliasing artifacts that were not suppressed by the standard UNFOLD technique could be successfully removed. Better image quality, temporal stability, and activation maps could be achieved by the proposed method. Conclusion: The proposed method can improve the effectiveness of the UNFOLD technique in removing aliasing artifacts when spectral filtering is kept minimal to preserve temporal resolution.",
keywords = "Aliasing artifacts, Bold fMRI, Phase trend removal, Spiral, UNFOLD",
author = "Yanle Hu",
year = "2011",
month = "3",
doi = "10.1002/jmri.22455",
language = "English (US)",
volume = "33",
pages = "742--747",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - Detrending phase drift

T2 - A preprocessing step to improve the effectiveness of the UNFOLD technique

AU - Hu, Yanle

PY - 2011/3

Y1 - 2011/3

N2 - Purpose: To improve the effectiveness of the UNFOLD technique in removing aliasing artifacts by detrending temporal phase drift in each voxel before the implementation of the UNFOLD technique. This is because linear and quadratic phase trends in temporal signal can shift and broaden aliasing peaks in the spectrum and cause the removal of aliasing artifacts by spectral filtering to be insufficient or even fail when minimal filtering of the spectrum is used. Materials and Methods: A functional magnetic resonance imaging (fMRI) study with a visual stimulus was performed on normal subjects to test the hypothesis. A 2D spiral-in/out sequence was used to acquire k-space data. Undersampled k-space trajectories were used to improve temporal resolution. Aliasing artifacts were removed by the UNFOLD technique. For comparison, two image sets, with and without phase trends removal, were obtained from each set of functional data. Results: After detrending temporal phase drift, residual aliasing artifacts that were not suppressed by the standard UNFOLD technique could be successfully removed. Better image quality, temporal stability, and activation maps could be achieved by the proposed method. Conclusion: The proposed method can improve the effectiveness of the UNFOLD technique in removing aliasing artifacts when spectral filtering is kept minimal to preserve temporal resolution.

AB - Purpose: To improve the effectiveness of the UNFOLD technique in removing aliasing artifacts by detrending temporal phase drift in each voxel before the implementation of the UNFOLD technique. This is because linear and quadratic phase trends in temporal signal can shift and broaden aliasing peaks in the spectrum and cause the removal of aliasing artifacts by spectral filtering to be insufficient or even fail when minimal filtering of the spectrum is used. Materials and Methods: A functional magnetic resonance imaging (fMRI) study with a visual stimulus was performed on normal subjects to test the hypothesis. A 2D spiral-in/out sequence was used to acquire k-space data. Undersampled k-space trajectories were used to improve temporal resolution. Aliasing artifacts were removed by the UNFOLD technique. For comparison, two image sets, with and without phase trends removal, were obtained from each set of functional data. Results: After detrending temporal phase drift, residual aliasing artifacts that were not suppressed by the standard UNFOLD technique could be successfully removed. Better image quality, temporal stability, and activation maps could be achieved by the proposed method. Conclusion: The proposed method can improve the effectiveness of the UNFOLD technique in removing aliasing artifacts when spectral filtering is kept minimal to preserve temporal resolution.

KW - Aliasing artifacts

KW - Bold fMRI

KW - Phase trend removal

KW - Spiral

KW - UNFOLD

UR - http://www.scopus.com/inward/record.url?scp=79952272095&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79952272095&partnerID=8YFLogxK

U2 - 10.1002/jmri.22455

DO - 10.1002/jmri.22455

M3 - Article

C2 - 21563260

AN - SCOPUS:79952272095

VL - 33

SP - 742

EP - 747

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 3

ER -