Abstract

A methodology was developed for determining the compressive properties of the supraspinatus tendon, based on finite element principles. Simplified three-dimensional models were created based on anatomical thickness measurements of unloaded supraspinatus tendons over 15 points. The tendon material was characterized as a composite structure of longitudinally arranged collagen fibers within an extrafibrillar matrix. The matrix was formulated as a hyperelastic material described by the Ogden form of the strain energy potential. The hyperelastic material parameters were parametrically manipulated until the analytical load-displacement results were similar to the results obtained from indentation testing. In the geometrically averaged tendon, the average ratio of experimental to theoretical maximum indentation displacement was 1.00 (SD: 0.01). The average normalization of residuals was 2.1 g (SD: 0.9g). Therefore, rite compressive material properties of the supraspinatus tendon extrafibrillar matrix were adequately derived with a first-order hyperelastic formulation. The initial compressive elastic modulus ranged from 0.024 to 0.090 MPa over the tendon surface and increased nonlinearly with additional compression. Using these material properties, the stresses induced during acromional impingement can be analyzed.

Original languageEnglish (US)
Pages (from-to)47-51
Number of pages5
JournalJournal of Biomechanical Engineering
Volume123
Issue number1
DOIs
StatePublished - 2001

Fingerprint

Rotator Cuff
Tendons
Materials properties
Indentation
Thickness measurement
Elastic Modulus
Strain energy
Composite structures
Collagen
Compaction
Elastic moduli
Fibers
Testing

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biophysics

Cite this

Determination of the compressive material properties of the supraspinatus tendon. / Zobitz, M. E.; Luo, Z. P.; An, K. N.

In: Journal of Biomechanical Engineering, Vol. 123, No. 1, 2001, p. 47-51.

Research output: Contribution to journalArticle

Zobitz, M. E. ; Luo, Z. P. ; An, K. N. / Determination of the compressive material properties of the supraspinatus tendon. In: Journal of Biomechanical Engineering. 2001 ; Vol. 123, No. 1. pp. 47-51.
@article{60a1899db1864d329488835f02b1ec07,
title = "Determination of the compressive material properties of the supraspinatus tendon",
abstract = "A methodology was developed for determining the compressive properties of the supraspinatus tendon, based on finite element principles. Simplified three-dimensional models were created based on anatomical thickness measurements of unloaded supraspinatus tendons over 15 points. The tendon material was characterized as a composite structure of longitudinally arranged collagen fibers within an extrafibrillar matrix. The matrix was formulated as a hyperelastic material described by the Ogden form of the strain energy potential. The hyperelastic material parameters were parametrically manipulated until the analytical load-displacement results were similar to the results obtained from indentation testing. In the geometrically averaged tendon, the average ratio of experimental to theoretical maximum indentation displacement was 1.00 (SD: 0.01). The average normalization of residuals was 2.1 g (SD: 0.9g). Therefore, rite compressive material properties of the supraspinatus tendon extrafibrillar matrix were adequately derived with a first-order hyperelastic formulation. The initial compressive elastic modulus ranged from 0.024 to 0.090 MPa over the tendon surface and increased nonlinearly with additional compression. Using these material properties, the stresses induced during acromional impingement can be analyzed.",
author = "Zobitz, {M. E.} and Luo, {Z. P.} and An, {K. N.}",
year = "2001",
doi = "10.1115/1.1339816",
language = "English (US)",
volume = "123",
pages = "47--51",
journal = "Journal of Biomechanical Engineering",
issn = "0148-0731",
publisher = "American Society of Mechanical Engineers(ASME)",
number = "1",

}

TY - JOUR

T1 - Determination of the compressive material properties of the supraspinatus tendon

AU - Zobitz, M. E.

AU - Luo, Z. P.

AU - An, K. N.

PY - 2001

Y1 - 2001

N2 - A methodology was developed for determining the compressive properties of the supraspinatus tendon, based on finite element principles. Simplified three-dimensional models were created based on anatomical thickness measurements of unloaded supraspinatus tendons over 15 points. The tendon material was characterized as a composite structure of longitudinally arranged collagen fibers within an extrafibrillar matrix. The matrix was formulated as a hyperelastic material described by the Ogden form of the strain energy potential. The hyperelastic material parameters were parametrically manipulated until the analytical load-displacement results were similar to the results obtained from indentation testing. In the geometrically averaged tendon, the average ratio of experimental to theoretical maximum indentation displacement was 1.00 (SD: 0.01). The average normalization of residuals was 2.1 g (SD: 0.9g). Therefore, rite compressive material properties of the supraspinatus tendon extrafibrillar matrix were adequately derived with a first-order hyperelastic formulation. The initial compressive elastic modulus ranged from 0.024 to 0.090 MPa over the tendon surface and increased nonlinearly with additional compression. Using these material properties, the stresses induced during acromional impingement can be analyzed.

AB - A methodology was developed for determining the compressive properties of the supraspinatus tendon, based on finite element principles. Simplified three-dimensional models were created based on anatomical thickness measurements of unloaded supraspinatus tendons over 15 points. The tendon material was characterized as a composite structure of longitudinally arranged collagen fibers within an extrafibrillar matrix. The matrix was formulated as a hyperelastic material described by the Ogden form of the strain energy potential. The hyperelastic material parameters were parametrically manipulated until the analytical load-displacement results were similar to the results obtained from indentation testing. In the geometrically averaged tendon, the average ratio of experimental to theoretical maximum indentation displacement was 1.00 (SD: 0.01). The average normalization of residuals was 2.1 g (SD: 0.9g). Therefore, rite compressive material properties of the supraspinatus tendon extrafibrillar matrix were adequately derived with a first-order hyperelastic formulation. The initial compressive elastic modulus ranged from 0.024 to 0.090 MPa over the tendon surface and increased nonlinearly with additional compression. Using these material properties, the stresses induced during acromional impingement can be analyzed.

UR - http://www.scopus.com/inward/record.url?scp=0035096172&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035096172&partnerID=8YFLogxK

U2 - 10.1115/1.1339816

DO - 10.1115/1.1339816

M3 - Article

C2 - 11277301

AN - SCOPUS:0035096172

VL - 123

SP - 47

EP - 51

JO - Journal of Biomechanical Engineering

JF - Journal of Biomechanical Engineering

SN - 0148-0731

IS - 1

ER -