Continuous monitoring of intraocular pressure: Rationale and progress toward a clinical device

Research output: Contribution to journalArticle

43 Citations (Scopus)

Abstract

Intraocular pressure (IOP) is a dynamic physiologic parameter with regular circadian variations and unpredictable short-term and long-term fluctuations. Current methods of measuring IOP are suboptimal with a typical clinical practice only performing periodic IOP measurements during regular office hours. Diurnal and 24-hour IOP measurements obtained on an in-patient basis can increase measurements but are inconvenient and expensive, and do not allow ambulatory monitoring of IOP. The goal of continuous IOP monitoring is to provide automated 24-hour recording of ambulatory IOP. Continuous IOP monitoring involves 2 complementary paradigms. Temporary noninvasive monitoring, possibly involving a contact lens-based pressure sensor, would be used to measure 24-hour IOP on a periodic basis. Permanent monitoring would be more invasive, using an implantable pressure sensor. Despite numerous previous attempts at continuous IOP monitoring, a device suitable for clinical use is not yet available. However, devices currently in development for permanent IOP monitoring seem to be nearly ready for human testing. The technologic issues for temporary monitoring may be greater than for permanent monitoring.

Original languageEnglish (US)
Pages (from-to)272-279
Number of pages8
JournalJournal of Glaucoma
Volume18
Issue number4
DOIs
StatePublished - Apr 2009

Fingerprint

Intraocular Pressure
Equipment and Supplies
Pressure
Ambulatory Monitoring
Contact Lenses

Keywords

  • Circadian rhythms
  • Intraocular pressure
  • Telemetry
  • Tonometry

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Continuous monitoring of intraocular pressure : Rationale and progress toward a clinical device. / Sit, Arthur J.

In: Journal of Glaucoma, Vol. 18, No. 4, 04.2009, p. 272-279.

Research output: Contribution to journalArticle

@article{b8a56b248aa84c8d9b53d1e82308d46c,
title = "Continuous monitoring of intraocular pressure: Rationale and progress toward a clinical device",
abstract = "Intraocular pressure (IOP) is a dynamic physiologic parameter with regular circadian variations and unpredictable short-term and long-term fluctuations. Current methods of measuring IOP are suboptimal with a typical clinical practice only performing periodic IOP measurements during regular office hours. Diurnal and 24-hour IOP measurements obtained on an in-patient basis can increase measurements but are inconvenient and expensive, and do not allow ambulatory monitoring of IOP. The goal of continuous IOP monitoring is to provide automated 24-hour recording of ambulatory IOP. Continuous IOP monitoring involves 2 complementary paradigms. Temporary noninvasive monitoring, possibly involving a contact lens-based pressure sensor, would be used to measure 24-hour IOP on a periodic basis. Permanent monitoring would be more invasive, using an implantable pressure sensor. Despite numerous previous attempts at continuous IOP monitoring, a device suitable for clinical use is not yet available. However, devices currently in development for permanent IOP monitoring seem to be nearly ready for human testing. The technologic issues for temporary monitoring may be greater than for permanent monitoring.",
keywords = "Circadian rhythms, Intraocular pressure, Telemetry, Tonometry",
author = "Sit, {Arthur J}",
year = "2009",
month = "4",
doi = "10.1097/IJG.0b013e3181862490",
language = "English (US)",
volume = "18",
pages = "272--279",
journal = "Journal of Glaucoma",
issn = "1057-0829",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

TY - JOUR

T1 - Continuous monitoring of intraocular pressure

T2 - Rationale and progress toward a clinical device

AU - Sit, Arthur J

PY - 2009/4

Y1 - 2009/4

N2 - Intraocular pressure (IOP) is a dynamic physiologic parameter with regular circadian variations and unpredictable short-term and long-term fluctuations. Current methods of measuring IOP are suboptimal with a typical clinical practice only performing periodic IOP measurements during regular office hours. Diurnal and 24-hour IOP measurements obtained on an in-patient basis can increase measurements but are inconvenient and expensive, and do not allow ambulatory monitoring of IOP. The goal of continuous IOP monitoring is to provide automated 24-hour recording of ambulatory IOP. Continuous IOP monitoring involves 2 complementary paradigms. Temporary noninvasive monitoring, possibly involving a contact lens-based pressure sensor, would be used to measure 24-hour IOP on a periodic basis. Permanent monitoring would be more invasive, using an implantable pressure sensor. Despite numerous previous attempts at continuous IOP monitoring, a device suitable for clinical use is not yet available. However, devices currently in development for permanent IOP monitoring seem to be nearly ready for human testing. The technologic issues for temporary monitoring may be greater than for permanent monitoring.

AB - Intraocular pressure (IOP) is a dynamic physiologic parameter with regular circadian variations and unpredictable short-term and long-term fluctuations. Current methods of measuring IOP are suboptimal with a typical clinical practice only performing periodic IOP measurements during regular office hours. Diurnal and 24-hour IOP measurements obtained on an in-patient basis can increase measurements but are inconvenient and expensive, and do not allow ambulatory monitoring of IOP. The goal of continuous IOP monitoring is to provide automated 24-hour recording of ambulatory IOP. Continuous IOP monitoring involves 2 complementary paradigms. Temporary noninvasive monitoring, possibly involving a contact lens-based pressure sensor, would be used to measure 24-hour IOP on a periodic basis. Permanent monitoring would be more invasive, using an implantable pressure sensor. Despite numerous previous attempts at continuous IOP monitoring, a device suitable for clinical use is not yet available. However, devices currently in development for permanent IOP monitoring seem to be nearly ready for human testing. The technologic issues for temporary monitoring may be greater than for permanent monitoring.

KW - Circadian rhythms

KW - Intraocular pressure

KW - Telemetry

KW - Tonometry

UR - http://www.scopus.com/inward/record.url?scp=67651174406&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67651174406&partnerID=8YFLogxK

U2 - 10.1097/IJG.0b013e3181862490

DO - 10.1097/IJG.0b013e3181862490

M3 - Article

C2 - 19365190

AN - SCOPUS:67651174406

VL - 18

SP - 272

EP - 279

JO - Journal of Glaucoma

JF - Journal of Glaucoma

SN - 1057-0829

IS - 4

ER -