Contemporary management of cardiovascular implantable electronic device infections

Muhammad R. Sohail, Omer W. Sultan, Sania S. Raza

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Cardiovascular implantable electronic device (CIED) implantation rate has substantially risen in the foregoing decades. Unfortunately, this upsurge in CIED implantation rate has been accompanied by a disproportionate rise in the rate of CIED infections. Device infection is a major complication of CIED implantation, necessitating removal of an infected device followed by systemic antimicrobial therapy and reimplantation of a new system. In this article, we review the current epidemiology, risk factors, diagnostic strategy and contemporary management of CIED infection. In addition, we address the vexing question of how to best manage patients with Staphylococcus aureus bacteremia, in the setting of an implanted device, but no overt clinical signs of CIED infection. Lastly, we discuss the preventive strategies to minimize risk of CIED infection.

Original languageEnglish (US)
Pages (from-to)831-839
Number of pages9
JournalExpert Review of Anti-Infective Therapy
Volume8
Issue number7
DOIs
StatePublished - Jul 2010

Fingerprint

Equipment and Supplies
Infection
Device Removal
Replantation
Bacteremia
Staphylococcus aureus
Epidemiology

Keywords

  • Cardiovascular implantable electronic device
  • Defibrillator
  • Infection
  • Pacemaker

ASJC Scopus subject areas

  • Microbiology
  • Virology
  • Infectious Diseases
  • Microbiology (medical)

Cite this

Contemporary management of cardiovascular implantable electronic device infections. / Sohail, Muhammad R.; Sultan, Omer W.; Raza, Sania S.

In: Expert Review of Anti-Infective Therapy, Vol. 8, No. 7, 07.2010, p. 831-839.

Research output: Contribution to journalArticle

Sohail, Muhammad R. ; Sultan, Omer W. ; Raza, Sania S. / Contemporary management of cardiovascular implantable electronic device infections. In: Expert Review of Anti-Infective Therapy. 2010 ; Vol. 8, No. 7. pp. 831-839.
@article{c9281ec0500945af9b85fe0c28078a55,
title = "Contemporary management of cardiovascular implantable electronic device infections",
abstract = "Cardiovascular implantable electronic device (CIED) implantation rate has substantially risen in the foregoing decades. Unfortunately, this upsurge in CIED implantation rate has been accompanied by a disproportionate rise in the rate of CIED infections. Device infection is a major complication of CIED implantation, necessitating removal of an infected device followed by systemic antimicrobial therapy and reimplantation of a new system. In this article, we review the current epidemiology, risk factors, diagnostic strategy and contemporary management of CIED infection. In addition, we address the vexing question of how to best manage patients with Staphylococcus aureus bacteremia, in the setting of an implanted device, but no overt clinical signs of CIED infection. Lastly, we discuss the preventive strategies to minimize risk of CIED infection.",
keywords = "Cardiovascular implantable electronic device, Defibrillator, Infection, Pacemaker",
author = "Sohail, {Muhammad R.} and Sultan, {Omer W.} and Raza, {Sania S.}",
year = "2010",
month = "7",
doi = "10.1586/eri.10.54",
language = "English (US)",
volume = "8",
pages = "831--839",
journal = "Expert Review of Anti-Infective Therapy",
issn = "1478-7210",
publisher = "Expert Reviews Ltd.",
number = "7",

}

TY - JOUR

T1 - Contemporary management of cardiovascular implantable electronic device infections

AU - Sohail, Muhammad R.

AU - Sultan, Omer W.

AU - Raza, Sania S.

PY - 2010/7

Y1 - 2010/7

N2 - Cardiovascular implantable electronic device (CIED) implantation rate has substantially risen in the foregoing decades. Unfortunately, this upsurge in CIED implantation rate has been accompanied by a disproportionate rise in the rate of CIED infections. Device infection is a major complication of CIED implantation, necessitating removal of an infected device followed by systemic antimicrobial therapy and reimplantation of a new system. In this article, we review the current epidemiology, risk factors, diagnostic strategy and contemporary management of CIED infection. In addition, we address the vexing question of how to best manage patients with Staphylococcus aureus bacteremia, in the setting of an implanted device, but no overt clinical signs of CIED infection. Lastly, we discuss the preventive strategies to minimize risk of CIED infection.

AB - Cardiovascular implantable electronic device (CIED) implantation rate has substantially risen in the foregoing decades. Unfortunately, this upsurge in CIED implantation rate has been accompanied by a disproportionate rise in the rate of CIED infections. Device infection is a major complication of CIED implantation, necessitating removal of an infected device followed by systemic antimicrobial therapy and reimplantation of a new system. In this article, we review the current epidemiology, risk factors, diagnostic strategy and contemporary management of CIED infection. In addition, we address the vexing question of how to best manage patients with Staphylococcus aureus bacteremia, in the setting of an implanted device, but no overt clinical signs of CIED infection. Lastly, we discuss the preventive strategies to minimize risk of CIED infection.

KW - Cardiovascular implantable electronic device

KW - Defibrillator

KW - Infection

KW - Pacemaker

UR - http://www.scopus.com/inward/record.url?scp=77954241402&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77954241402&partnerID=8YFLogxK

U2 - 10.1586/eri.10.54

DO - 10.1586/eri.10.54

M3 - Article

C2 - 20586567

AN - SCOPUS:77954241402

VL - 8

SP - 831

EP - 839

JO - Expert Review of Anti-Infective Therapy

JF - Expert Review of Anti-Infective Therapy

SN - 1478-7210

IS - 7

ER -