Construction of realistic phantoms from patient images and a commercial three-dimensional printer

Shuai Leng, Baiyu Chen, Thomas Vrieze, Joel Kuhlmann, Lifeng Yu, Amy Alexander, Jane Matsumoto, Jonathan Morris, Cynthia H McCollough

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The purpose of this study was to use three-dimensional (3-D) printing techniques to construct liver and brain phantoms having realistic pathologies, anatomic structures, and heterogeneous backgrounds. Patient liver and head computed tomography (CT) images were segmented into tissue, vessels, liver lesion, white and gray matter, and cerebrospinal fluid (CSF). Stereolithography files of each object were created and imported into a commercial 3-D printer. Printing materials were assigned to each object after test scans, which showed that the printing materials had CT numbers ranging from 70 to 121 HU at 120 kV. Printed phantoms were scanned on a CT scanner and images were evaluated. CT images of the liver phantom had measured CT numbers of 77.8 and 96.6 HU for the lesion and background, and 137.5 to 428.4 HU for the vessels channels, which were filled with iodine solutions. The difference in CT numbers between lesions and background (18.8 HU) was representative of the low-contrast values needed for optimization tasks. The liver phantom background was evaluated with Haralick features and showed similar texture between patient and phantom images. CT images of the brain phantom had CT numbers of 125, 134, and 108 HU for white matter, gray matter, and CSF, respectively. The CT number differences were similar to those in patient images.

Original languageEnglish (US)
Article number033501
JournalJournal of Medical Imaging
Volume3
Issue number3
DOIs
StatePublished - Jul 1 2016

Fingerprint

Tomography
Liver
Printing
Cerebrospinal fluid
Cerebrospinal Fluid
Brain
X-Ray Computed Tomography Scanners
3D printers
Stereolithography
Iodine
Pathology
Head
Textures
Tissue

Keywords

  • brain
  • computed tomography
  • image quality
  • liver
  • phantom
  • three-dimensional printer

ASJC Scopus subject areas

  • Bioengineering
  • Radiology Nuclear Medicine and imaging

Cite this

Construction of realistic phantoms from patient images and a commercial three-dimensional printer. / Leng, Shuai; Chen, Baiyu; Vrieze, Thomas; Kuhlmann, Joel; Yu, Lifeng; Alexander, Amy; Matsumoto, Jane; Morris, Jonathan; McCollough, Cynthia H.

In: Journal of Medical Imaging, Vol. 3, No. 3, 033501, 01.07.2016.

Research output: Contribution to journalArticle

Leng, Shuai ; Chen, Baiyu ; Vrieze, Thomas ; Kuhlmann, Joel ; Yu, Lifeng ; Alexander, Amy ; Matsumoto, Jane ; Morris, Jonathan ; McCollough, Cynthia H. / Construction of realistic phantoms from patient images and a commercial three-dimensional printer. In: Journal of Medical Imaging. 2016 ; Vol. 3, No. 3.
@article{ef4f0e47ef0944bc90ad5ead5360fe25,
title = "Construction of realistic phantoms from patient images and a commercial three-dimensional printer",
abstract = "The purpose of this study was to use three-dimensional (3-D) printing techniques to construct liver and brain phantoms having realistic pathologies, anatomic structures, and heterogeneous backgrounds. Patient liver and head computed tomography (CT) images were segmented into tissue, vessels, liver lesion, white and gray matter, and cerebrospinal fluid (CSF). Stereolithography files of each object were created and imported into a commercial 3-D printer. Printing materials were assigned to each object after test scans, which showed that the printing materials had CT numbers ranging from 70 to 121 HU at 120 kV. Printed phantoms were scanned on a CT scanner and images were evaluated. CT images of the liver phantom had measured CT numbers of 77.8 and 96.6 HU for the lesion and background, and 137.5 to 428.4 HU for the vessels channels, which were filled with iodine solutions. The difference in CT numbers between lesions and background (18.8 HU) was representative of the low-contrast values needed for optimization tasks. The liver phantom background was evaluated with Haralick features and showed similar texture between patient and phantom images. CT images of the brain phantom had CT numbers of 125, 134, and 108 HU for white matter, gray matter, and CSF, respectively. The CT number differences were similar to those in patient images.",
keywords = "brain, computed tomography, image quality, liver, phantom, three-dimensional printer",
author = "Shuai Leng and Baiyu Chen and Thomas Vrieze and Joel Kuhlmann and Lifeng Yu and Amy Alexander and Jane Matsumoto and Jonathan Morris and McCollough, {Cynthia H}",
year = "2016",
month = "7",
day = "1",
doi = "10.1117/1.JMI.3.3.033501",
language = "English (US)",
volume = "3",
journal = "Journal of Medical Imaging",
issn = "0720-048X",
publisher = "Elsevier Ireland Ltd",
number = "3",

}

TY - JOUR

T1 - Construction of realistic phantoms from patient images and a commercial three-dimensional printer

AU - Leng, Shuai

AU - Chen, Baiyu

AU - Vrieze, Thomas

AU - Kuhlmann, Joel

AU - Yu, Lifeng

AU - Alexander, Amy

AU - Matsumoto, Jane

AU - Morris, Jonathan

AU - McCollough, Cynthia H

PY - 2016/7/1

Y1 - 2016/7/1

N2 - The purpose of this study was to use three-dimensional (3-D) printing techniques to construct liver and brain phantoms having realistic pathologies, anatomic structures, and heterogeneous backgrounds. Patient liver and head computed tomography (CT) images were segmented into tissue, vessels, liver lesion, white and gray matter, and cerebrospinal fluid (CSF). Stereolithography files of each object were created and imported into a commercial 3-D printer. Printing materials were assigned to each object after test scans, which showed that the printing materials had CT numbers ranging from 70 to 121 HU at 120 kV. Printed phantoms were scanned on a CT scanner and images were evaluated. CT images of the liver phantom had measured CT numbers of 77.8 and 96.6 HU for the lesion and background, and 137.5 to 428.4 HU for the vessels channels, which were filled with iodine solutions. The difference in CT numbers between lesions and background (18.8 HU) was representative of the low-contrast values needed for optimization tasks. The liver phantom background was evaluated with Haralick features and showed similar texture between patient and phantom images. CT images of the brain phantom had CT numbers of 125, 134, and 108 HU for white matter, gray matter, and CSF, respectively. The CT number differences were similar to those in patient images.

AB - The purpose of this study was to use three-dimensional (3-D) printing techniques to construct liver and brain phantoms having realistic pathologies, anatomic structures, and heterogeneous backgrounds. Patient liver and head computed tomography (CT) images were segmented into tissue, vessels, liver lesion, white and gray matter, and cerebrospinal fluid (CSF). Stereolithography files of each object were created and imported into a commercial 3-D printer. Printing materials were assigned to each object after test scans, which showed that the printing materials had CT numbers ranging from 70 to 121 HU at 120 kV. Printed phantoms were scanned on a CT scanner and images were evaluated. CT images of the liver phantom had measured CT numbers of 77.8 and 96.6 HU for the lesion and background, and 137.5 to 428.4 HU for the vessels channels, which were filled with iodine solutions. The difference in CT numbers between lesions and background (18.8 HU) was representative of the low-contrast values needed for optimization tasks. The liver phantom background was evaluated with Haralick features and showed similar texture between patient and phantom images. CT images of the brain phantom had CT numbers of 125, 134, and 108 HU for white matter, gray matter, and CSF, respectively. The CT number differences were similar to those in patient images.

KW - brain

KW - computed tomography

KW - image quality

KW - liver

KW - phantom

KW - three-dimensional printer

UR - http://www.scopus.com/inward/record.url?scp=84991525179&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84991525179&partnerID=8YFLogxK

U2 - 10.1117/1.JMI.3.3.033501

DO - 10.1117/1.JMI.3.3.033501

M3 - Article

VL - 3

JO - Journal of Medical Imaging

JF - Journal of Medical Imaging

SN - 0720-048X

IS - 3

M1 - 033501

ER -