TY - JOUR
T1 - Comparison of the early haemodynamics of stented pericardial and porcine aortic valves
AU - Sharma, Vikas
AU - Deo, Salil V.
AU - Altarabsheh, Salah E.
AU - Cho, Yan Hyun
AU - Erwin, Patricia J.
AU - Park, Soon J.
N1 - Publisher Copyright:
© The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
PY - 2014/1
Y1 - 2014/1
N2 - Data comparing the haemodynamic performance of stented pericardial and porcine aortic valves are conflicting. Hence, we performed a systematic review and meta-analysis comparing the early haemodynamic parameters of stented pericardial and porcine valves in patients undergoing isolated aortic valve replacement. Medline, EMBASE and Web of Science were queried for English language original publications from 2000 to 2013. Studies comparing porcine (PoV) and pericardial (PeV) with regard to their haemodynamic parameters were included in this review. Continuous data were pooled using the mean difference (MD) or the standardized mean difference (SMD). A random-effect inverse weighted analysis was conducted; a P-value <0.05 is considered statistically significant. Results are presented with 95% confidence intervals. Thirteen studies (1265 PeV patients and 871 PoV patients) were included in this analysis. The pooled transvalvular mean gradient was lower for PeV [MD -4.6 (-6.45 to -2.77) mmHg; P < 0.01]. Limiting this analysis to small valves (19 and 21 mm; eight studies; 714 patients) revealed that the PeV gradients were significantly lower [MD -4.5 (-5.7 to -3.2); P = 0.001]. The corresponding effective orifice area of PeV was significantly larger than PoV [SMD 0.42 (0.15-0.69); P < 0.01]. A sensitivity analysis comprising only randomized controlled trials did not significantly alter results. When compared with porcine valves, stented pericardial aortic valves have lower mean transvalvular gradients early after implant. Even pericardial valves in smaller sizes (19 and 21 mm) have a better haemodynamic profile when compared with their counterparts.
AB - Data comparing the haemodynamic performance of stented pericardial and porcine aortic valves are conflicting. Hence, we performed a systematic review and meta-analysis comparing the early haemodynamic parameters of stented pericardial and porcine valves in patients undergoing isolated aortic valve replacement. Medline, EMBASE and Web of Science were queried for English language original publications from 2000 to 2013. Studies comparing porcine (PoV) and pericardial (PeV) with regard to their haemodynamic parameters were included in this review. Continuous data were pooled using the mean difference (MD) or the standardized mean difference (SMD). A random-effect inverse weighted analysis was conducted; a P-value <0.05 is considered statistically significant. Results are presented with 95% confidence intervals. Thirteen studies (1265 PeV patients and 871 PoV patients) were included in this analysis. The pooled transvalvular mean gradient was lower for PeV [MD -4.6 (-6.45 to -2.77) mmHg; P < 0.01]. Limiting this analysis to small valves (19 and 21 mm; eight studies; 714 patients) revealed that the PeV gradients were significantly lower [MD -4.5 (-5.7 to -3.2); P = 0.001]. The corresponding effective orifice area of PeV was significantly larger than PoV [SMD 0.42 (0.15-0.69); P < 0.01]. A sensitivity analysis comprising only randomized controlled trials did not significantly alter results. When compared with porcine valves, stented pericardial aortic valves have lower mean transvalvular gradients early after implant. Even pericardial valves in smaller sizes (19 and 21 mm) have a better haemodynamic profile when compared with their counterparts.
KW - Aortic valve
KW - Patient-prosthesis mismatch
KW - Stented pericardial bioprosthesis
KW - Stented porcine bioprosthesis
KW - Transvalvular gradient
UR - http://www.scopus.com/inward/record.url?scp=84936872022&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84936872022&partnerID=8YFLogxK
U2 - 10.1093/ejcts/ezu272
DO - 10.1093/ejcts/ezu272
M3 - Review article
C2 - 25123674
AN - SCOPUS:84936872022
SN - 1010-7940
VL - 47
SP - 4
EP - 10
JO - European Journal of Cardio-thoracic Surgery
JF - European Journal of Cardio-thoracic Surgery
IS - 1
ER -