Combined use of off-pump techniques and a sutureless proximal aortic anastomotic device reduces cerebral microemboli generation during coronary artery bypass grafting

John E. Scarborough, William White, Frantz E. Derilus, Joseph P. Mathew, Mark F. Newman, Kevin P. Landolfo

Research output: Contribution to journalArticlepeer-review

28 Scopus citations

Abstract

Objective: Intraoperative cerebral microemboli are associated with the development of postoperative stroke and neurocognitive decline in patients undergoing coronary artery bypass grafting. Although cardiopulmonary bypass is responsible for the generation of a significant number of such emboli, the elimination of cardiopulmonary bypass alone has not been conclusively shown to improve neurocognitive outcome. The current study was performed to determine the effects of combined off-pump coronary artery bypass grafting and sutureless proximal aortic anastomotic techniques on the generation of intraoperative cerebral microemboli compared with standard coronary artery bypass grafting techniques of cardiopulmonary bypass and hand-sewn proximal anastomoses. Methods: Fifty-three patients underwent off-pump coronary artery bypass grafting by using the sutureless Symmetry aortic connector device (St Jude Medical, St Paul, Minn) for all proximal anastomoses. Eighteen of these patients received intraoperative transcranial Doppler ultrasonography to determine right- and left-sided cerebral microembolic counts. These results were compared with those obtained from a similar group of 17 patients undergoing standard coronary artery bypass grafting, in whom cardiopulmonary bypass and hand-sewn proximal anastomoses were used. Results: Our use of the proximal anastomotic device in patients undergoing coronary artery bypass grafting was safe, with no aortic complications, postoperative strokes, or in-hospital deaths. Microembolic counts to both the right and left cerebral circulation were significantly reduced in the patients undergoing off-pump coronary artery bypass grafting (right = 21.9 ± 20.7 emboli, left = 24.9 ± 19.2 emboli) compared with those in patients undergoing standard coronary artery bypass grafting (right = 181.6 ±85.3, left = 189.9 ± 60.401, P < .0001). Conclusions: Our use of a sutureless proximal anastomotic device during off-pump coronary artery bypass grafting is safe and significantly decreases cerebral microembolism when compared with standard coronary artery bypass grafting with cardiopulmonary bypass and hand-sewn anastomoses. Long-term follow-up is needed to determine the effects of this technical strategy on neurocognitive outcome.

Original languageEnglish (US)
Pages (from-to)1561-1567
Number of pages7
JournalJournal of Thoracic and Cardiovascular Surgery
Volume126
Issue number5
DOIs
StatePublished - Nov 2003

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Combined use of off-pump techniques and a sutureless proximal aortic anastomotic device reduces cerebral microemboli generation during coronary artery bypass grafting'. Together they form a unique fingerprint.

Cite this