TY - JOUR
T1 - Clinical applications of neurochemical and electrophysiological measurements for closed-loop neurostimulation
AU - Price, J. Blair
AU - Rusheen, Aaron E.
AU - Barath, Abhijeet S.
AU - Rojas Cabrera, Juan M.
AU - Shin, Hojin
AU - Chang, Su Youne
AU - Kimble, Christopher J.
AU - Bennet, Kevin E.
AU - Blaha, Charles D.
AU - Lee, Kendall H.
AU - Oh, Yoonbae
N1 - Funding Information:
This research was supported by NIH award nos. R01NS112176 and R01NS088260.
Publisher Copyright:
© AANS 2020.
PY - 2020/7/1
Y1 - 2020/7/1
N2 - The development of closed-loop deep brain stimulation (DBS) systems represents a significant opportunity for innovation in the clinical application of neurostimulation therapies. Despite the highly dynamic nature of neurological diseases, open-loop DBS applications are incapable of modifying parameters in real time to react to fluctuations in disease states. Thus, current practice for the designation of stimulation parameters, such as duration, amplitude, and pulse frequency, is an algorithmic process. Ideal stimulation parameters are highly individualized and must reflect both the specific disease presentation and the unique pathophysiology presented by the individual. Stimulation parameters currently require a lengthy trial-and-error process to achieve the maximal therapeutic effect and can only be modified during clinical visits. The major impediment to the development of automated, adaptive closed-loop systems involves the selection of highly specific disease-related biomarkers to provide feedback for the stimulation platform. This review explores the disease relevance of neurochemical and electrophysiological biomarkers for the development of closed-loop neurostimulation technologies. Electrophysiological biomarkers, such as local field potentials, have been used to monitor disease states. Real-time measurement of neurochemical substances may be similarly useful for disease characterization. Thus, the introduction of measurable neurochemical analytes has significantly expanded biomarker options for feedback-sensitive neuromodulation systems. The potential use of biomarker monitoring to advance neurostimulation approaches for treatment of Parkinson's disease, essential tremor, epilepsy, Tourette syndrome, obsessive-compulsive disorder, chronic pain, and depression is examined. Further, challenges and advances in the development of closed-loop neurostimulation technology are reviewed, as well as opportunities for next-generation closed-loop platforms.
AB - The development of closed-loop deep brain stimulation (DBS) systems represents a significant opportunity for innovation in the clinical application of neurostimulation therapies. Despite the highly dynamic nature of neurological diseases, open-loop DBS applications are incapable of modifying parameters in real time to react to fluctuations in disease states. Thus, current practice for the designation of stimulation parameters, such as duration, amplitude, and pulse frequency, is an algorithmic process. Ideal stimulation parameters are highly individualized and must reflect both the specific disease presentation and the unique pathophysiology presented by the individual. Stimulation parameters currently require a lengthy trial-and-error process to achieve the maximal therapeutic effect and can only be modified during clinical visits. The major impediment to the development of automated, adaptive closed-loop systems involves the selection of highly specific disease-related biomarkers to provide feedback for the stimulation platform. This review explores the disease relevance of neurochemical and electrophysiological biomarkers for the development of closed-loop neurostimulation technologies. Electrophysiological biomarkers, such as local field potentials, have been used to monitor disease states. Real-time measurement of neurochemical substances may be similarly useful for disease characterization. Thus, the introduction of measurable neurochemical analytes has significantly expanded biomarker options for feedback-sensitive neuromodulation systems. The potential use of biomarker monitoring to advance neurostimulation approaches for treatment of Parkinson's disease, essential tremor, epilepsy, Tourette syndrome, obsessive-compulsive disorder, chronic pain, and depression is examined. Further, challenges and advances in the development of closed-loop neurostimulation technology are reviewed, as well as opportunities for next-generation closed-loop platforms.
KW - Closed loop
KW - Deep brain stimulation
KW - Electrochemistry
KW - Electrophysiology
KW - Neurochemical measurement
KW - Open loop
UR - http://www.scopus.com/inward/record.url?scp=85087472353&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85087472353&partnerID=8YFLogxK
U2 - 10.3171/2020.4.FOCUS20167
DO - 10.3171/2020.4.FOCUS20167
M3 - Article
C2 - 32610297
AN - SCOPUS:85087472353
SN - 1092-0684
VL - 49
JO - Neurosurgical Focus
JF - Neurosurgical Focus
IS - 1
M1 - E6
ER -