Breast radiation dose with CESM compared with 2D FFDM and 3D tomosynthesis mammography

Judy R. James, William Pavlicek, James A. Hanson, Thomas F. Boltz, Bhavika K. Patel

Research output: Contribution to journalArticlepeer-review

38 Scopus citations

Abstract

OBJECTIVE. We aimed to compare radiation dose received during contrast-enhanced spectral mammography (CESM) using high- and low-energy projections with radiation dose received during 2D full field digital mammography (FFDM) and 3D tomosynthesis on phantoms and patients with varying breast thickness and density. MATERIALS AND METHODS. A single left craniocaudal projection was chosen to determine the doses for 6214 patients who underwent 2D FFDM, 3662 patients who underwent 3D tomosynthesis, and 173 patients who underwent CESM in this retrospective study. Dose measurements were also collected in phantoms with composition mimicking nondense and dense breast tissue. RESULTS. Average glandular dose (AGD) ± SD was 3.0 ± 1.1 mGy for CESM exposures at a mean breast thickness of 63 mm. At this thickness, the dose was 2.1 mGy from 2D FFDM and 2.5 mGy from 3D tomosynthesis. The nondense phantom had a mean AGD of 1.0 mGy with 2D FFDM, 1.3 mGy with 3D tomosynthesis, and 1.6 mGy with CESM. The dense breast phantom had a mean AGD of 1.3 mGy with 2D FFDM, 1.4 mGy with 3D tomosynthesis, and 2.1 mGy with CESM. At a compressed thickness of 4.5 cm, radiation exposure from CESM was approximately 25% higher in dense breast phantoms than in nondense breast phantoms. The dose in the dense phantom at a compressed thickness of 6 cm was approximately 42% higher than the dose in the nondense phantom at a compressed thickness of 4.5 cm. CONCLUSION. CESM was found to increase AGD at a mean breast thickness of 63 mm by approximately 0.9 mGy and 0.5 mGy compared with 2D FFDM and 3D tomosynthesis, respectively. Of note, CESM provides a standard image (similar to 2D FFDM) that is obtained using the low-energy projection. Overall, the AGD from CESM falls below the dose limit of 3 mGy set by Mammography Quality Standards Act regulations.

Original languageEnglish (US)
Pages (from-to)362-372
Number of pages11
JournalAmerican Journal of Roentgenology
Volume208
Issue number2
DOIs
StatePublished - Feb 2017

Keywords

  • 3D tomosynthesis
  • Breast imaging
  • Contrast-enhanced spectral mammography
  • Full field digital mammography
  • Radiation dose

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Breast radiation dose with CESM compared with 2D FFDM and 3D tomosynthesis mammography'. Together they form a unique fingerprint.

Cite this