Branching morphology of the rat hepatic portal vein tree: A micro-CT study

Jorn O. Den Buijs, Željko ̌ Bajzer, Erik L. Ritman

Research output: Contribution to journalArticle

40 Citations (Scopus)

Abstract

In contrast to the lung and the myocardium, the liver is a relatively homogeneous organ with fewer anatomic constraints on vascular branching. Hence, we hypothesize that the hepatic vasculature could more closely follow optimization of branching geometry than is the case in other organs. The geometrical and fractal properties of the rat hepatic portal vein tree were investigated, with the aid of three-dimensional micro-computed tomography data. Frequency distributions of vessel radii were obtained at three different voxel resolutions and fitted to a theoretical model of dichotomous branching. The model predicted an average junction exponent of 3.09. Hemodynamic model calculations showed that with generation, relative shear stress decreases. Branching angles were found to oscillate between those predicted by two optimality principles of minimum power loss and volume, and of minimum shear stress and surface. The liver shows a variation in branching morphology similar to that of other organs. Therefore, we conclude that anatomic constraints do not have a major perturbing impact.

Original languageEnglish (US)
Pages (from-to)1420-1428
Number of pages9
JournalAnnals of Biomedical Engineering
Volume34
Issue number9
DOIs
StatePublished - Sep 2006

Fingerprint

Rats
Liver
Shear stress
Hemodynamics
Fractals
Tomography
Geometry

Keywords

  • Blood flow
  • Fractality
  • Liver
  • Murray's law
  • Optimality

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Branching morphology of the rat hepatic portal vein tree : A micro-CT study. / Den Buijs, Jorn O.; Bajzer, Željko ̌; Ritman, Erik L.

In: Annals of Biomedical Engineering, Vol. 34, No. 9, 09.2006, p. 1420-1428.

Research output: Contribution to journalArticle

Den Buijs, Jorn O. ; Bajzer, Željko ̌ ; Ritman, Erik L. / Branching morphology of the rat hepatic portal vein tree : A micro-CT study. In: Annals of Biomedical Engineering. 2006 ; Vol. 34, No. 9. pp. 1420-1428.
@article{cc77863657214311b30ec18cc8d629b0,
title = "Branching morphology of the rat hepatic portal vein tree: A micro-CT study",
abstract = "In contrast to the lung and the myocardium, the liver is a relatively homogeneous organ with fewer anatomic constraints on vascular branching. Hence, we hypothesize that the hepatic vasculature could more closely follow optimization of branching geometry than is the case in other organs. The geometrical and fractal properties of the rat hepatic portal vein tree were investigated, with the aid of three-dimensional micro-computed tomography data. Frequency distributions of vessel radii were obtained at three different voxel resolutions and fitted to a theoretical model of dichotomous branching. The model predicted an average junction exponent of 3.09. Hemodynamic model calculations showed that with generation, relative shear stress decreases. Branching angles were found to oscillate between those predicted by two optimality principles of minimum power loss and volume, and of minimum shear stress and surface. The liver shows a variation in branching morphology similar to that of other organs. Therefore, we conclude that anatomic constraints do not have a major perturbing impact.",
keywords = "Blood flow, Fractality, Liver, Murray's law, Optimality",
author = "{Den Buijs}, {Jorn O.} and Bajzer, {Željko ̌} and Ritman, {Erik L.}",
year = "2006",
month = "9",
doi = "10.1007/s10439-006-9150-4",
language = "English (US)",
volume = "34",
pages = "1420--1428",
journal = "Annals of Biomedical Engineering",
issn = "0090-6964",
publisher = "Springer Netherlands",
number = "9",

}

TY - JOUR

T1 - Branching morphology of the rat hepatic portal vein tree

T2 - A micro-CT study

AU - Den Buijs, Jorn O.

AU - Bajzer, Željko ̌

AU - Ritman, Erik L.

PY - 2006/9

Y1 - 2006/9

N2 - In contrast to the lung and the myocardium, the liver is a relatively homogeneous organ with fewer anatomic constraints on vascular branching. Hence, we hypothesize that the hepatic vasculature could more closely follow optimization of branching geometry than is the case in other organs. The geometrical and fractal properties of the rat hepatic portal vein tree were investigated, with the aid of three-dimensional micro-computed tomography data. Frequency distributions of vessel radii were obtained at three different voxel resolutions and fitted to a theoretical model of dichotomous branching. The model predicted an average junction exponent of 3.09. Hemodynamic model calculations showed that with generation, relative shear stress decreases. Branching angles were found to oscillate between those predicted by two optimality principles of minimum power loss and volume, and of minimum shear stress and surface. The liver shows a variation in branching morphology similar to that of other organs. Therefore, we conclude that anatomic constraints do not have a major perturbing impact.

AB - In contrast to the lung and the myocardium, the liver is a relatively homogeneous organ with fewer anatomic constraints on vascular branching. Hence, we hypothesize that the hepatic vasculature could more closely follow optimization of branching geometry than is the case in other organs. The geometrical and fractal properties of the rat hepatic portal vein tree were investigated, with the aid of three-dimensional micro-computed tomography data. Frequency distributions of vessel radii were obtained at three different voxel resolutions and fitted to a theoretical model of dichotomous branching. The model predicted an average junction exponent of 3.09. Hemodynamic model calculations showed that with generation, relative shear stress decreases. Branching angles were found to oscillate between those predicted by two optimality principles of minimum power loss and volume, and of minimum shear stress and surface. The liver shows a variation in branching morphology similar to that of other organs. Therefore, we conclude that anatomic constraints do not have a major perturbing impact.

KW - Blood flow

KW - Fractality

KW - Liver

KW - Murray's law

KW - Optimality

UR - http://www.scopus.com/inward/record.url?scp=33748998796&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33748998796&partnerID=8YFLogxK

U2 - 10.1007/s10439-006-9150-4

DO - 10.1007/s10439-006-9150-4

M3 - Article

C2 - 16838126

AN - SCOPUS:33748998796

VL - 34

SP - 1420

EP - 1428

JO - Annals of Biomedical Engineering

JF - Annals of Biomedical Engineering

SN - 0090-6964

IS - 9

ER -