TY - JOUR
T1 - Automatic exposure control systems designed to maintain constant image noise
T2 - Effects on computed tomography dose and noise relative to clinically accepted technique charts
AU - Favazza, Christopher P.
AU - Yu, Lifeng
AU - Leng, Shuai
AU - Kofler, James M.
AU - McCollough, Cynthia H.
N1 - Publisher Copyright:
© 2015 Wolters Kluwer Health, Inc.
PY - 2015/5/29
Y1 - 2015/5/29
N2 - Objective To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. Materials and Methods A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. Results For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise-based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Conclusions Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects.
AB - Objective To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. Materials and Methods A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. Results For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise-based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Conclusions Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects.
KW - CT
KW - automatic exposure control
KW - image noise
KW - image quality
KW - radiation dose
UR - http://www.scopus.com/inward/record.url?scp=84930064120&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84930064120&partnerID=8YFLogxK
U2 - 10.1097/RCT.0000000000000221
DO - 10.1097/RCT.0000000000000221
M3 - Article
C2 - 25938214
AN - SCOPUS:84930064120
SN - 0363-8715
VL - 39
SP - 437
EP - 442
JO - Journal of Computer Assisted Tomography
JF - Journal of Computer Assisted Tomography
IS - 3
ER -