Automated stromal nerve rejection in corneal confocal images in vivo

Eric N. Brown, Jon J. Camp, Sanjay V. Patel, Jay W. McLaren, William M. Bourne, Richard A. Robb

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

With the advent of corneal confocal microscopy, investigators can determine keratocyte density in the corneal stroma in vivo. We and others have written automated algorithm to measure keratocyte density from human corneal confocal images. Such algorithms are only accurate if they exclude images of stromal nerve bundles (elongated objects) that would otherwise be counted as keratocytes. In this study we devised an algorithm to identify stromal nerve bundles and exclude them from measurements of keratocyte density. Nerve bundles were detected based on their size and aspect ratio, and were then subtracted from images by using a combination of morphology operations and direction calculations. The validity of nerve removal on measurements of keratocyte density was assessed. Keratocyte density was measured from confocal images of three normal human corneas in vivo by using our algorithm with nerve removal. After the same eyes underwent enucleation, density was measured manually from histologic sections. Keratocyte density was also measured from confocal images of 57 normal corneas in vivo (57 subjects) with and without nerve removal. In the three enucleated eyes, there was no significant difference between keratocyte density measured by automated counting with nerve removal and by histologic methods (P = 0.75). However, in the 57 normal corneas, use of the nerve-removal algorithm reduced estimates of density by 57.0±164.6 cells/mm 3 (mean±SD, p<0.038) in the anterior two-thirds of the stroma.

Original languageEnglish (US)
Title of host publicationProceedings of SPIE - The International Society for Optical Engineering
PublisherSociety of Photo-Optical Instrumentation Engineers
Volume3979
StatePublished - 2000
EventMedical Imaging 2000: Image Processing - San Diego, CA, USA
Duration: Feb 14 2000Feb 17 2000

Other

OtherMedical Imaging 2000: Image Processing
CitySan Diego, CA, USA
Period2/14/002/17/00

Fingerprint

nerves
rejection
cornea
bundles
Confocal microscopy
Aspect ratio
aspect ratio
counting
microscopy
estimates
cells

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Condensed Matter Physics

Cite this

Brown, E. N., Camp, J. J., Patel, S. V., McLaren, J. W., Bourne, W. M., & Robb, R. A. (2000). Automated stromal nerve rejection in corneal confocal images in vivo. In Proceedings of SPIE - The International Society for Optical Engineering (Vol. 3979). Society of Photo-Optical Instrumentation Engineers.

Automated stromal nerve rejection in corneal confocal images in vivo. / Brown, Eric N.; Camp, Jon J.; Patel, Sanjay V.; McLaren, Jay W.; Bourne, William M.; Robb, Richard A.

Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3979 Society of Photo-Optical Instrumentation Engineers, 2000.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Brown, EN, Camp, JJ, Patel, SV, McLaren, JW, Bourne, WM & Robb, RA 2000, Automated stromal nerve rejection in corneal confocal images in vivo. in Proceedings of SPIE - The International Society for Optical Engineering. vol. 3979, Society of Photo-Optical Instrumentation Engineers, Medical Imaging 2000: Image Processing, San Diego, CA, USA, 2/14/00.
Brown EN, Camp JJ, Patel SV, McLaren JW, Bourne WM, Robb RA. Automated stromal nerve rejection in corneal confocal images in vivo. In Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3979. Society of Photo-Optical Instrumentation Engineers. 2000
Brown, Eric N. ; Camp, Jon J. ; Patel, Sanjay V. ; McLaren, Jay W. ; Bourne, William M. ; Robb, Richard A. / Automated stromal nerve rejection in corneal confocal images in vivo. Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3979 Society of Photo-Optical Instrumentation Engineers, 2000.
@inproceedings{405606e07ad948b1a2f94cd10bed04b5,
title = "Automated stromal nerve rejection in corneal confocal images in vivo",
abstract = "With the advent of corneal confocal microscopy, investigators can determine keratocyte density in the corneal stroma in vivo. We and others have written automated algorithm to measure keratocyte density from human corneal confocal images. Such algorithms are only accurate if they exclude images of stromal nerve bundles (elongated objects) that would otherwise be counted as keratocytes. In this study we devised an algorithm to identify stromal nerve bundles and exclude them from measurements of keratocyte density. Nerve bundles were detected based on their size and aspect ratio, and were then subtracted from images by using a combination of morphology operations and direction calculations. The validity of nerve removal on measurements of keratocyte density was assessed. Keratocyte density was measured from confocal images of three normal human corneas in vivo by using our algorithm with nerve removal. After the same eyes underwent enucleation, density was measured manually from histologic sections. Keratocyte density was also measured from confocal images of 57 normal corneas in vivo (57 subjects) with and without nerve removal. In the three enucleated eyes, there was no significant difference between keratocyte density measured by automated counting with nerve removal and by histologic methods (P = 0.75). However, in the 57 normal corneas, use of the nerve-removal algorithm reduced estimates of density by 57.0±164.6 cells/mm 3 (mean±SD, p<0.038) in the anterior two-thirds of the stroma.",
author = "Brown, {Eric N.} and Camp, {Jon J.} and Patel, {Sanjay V.} and McLaren, {Jay W.} and Bourne, {William M.} and Robb, {Richard A.}",
year = "2000",
language = "English (US)",
volume = "3979",
booktitle = "Proceedings of SPIE - The International Society for Optical Engineering",
publisher = "Society of Photo-Optical Instrumentation Engineers",

}

TY - GEN

T1 - Automated stromal nerve rejection in corneal confocal images in vivo

AU - Brown, Eric N.

AU - Camp, Jon J.

AU - Patel, Sanjay V.

AU - McLaren, Jay W.

AU - Bourne, William M.

AU - Robb, Richard A.

PY - 2000

Y1 - 2000

N2 - With the advent of corneal confocal microscopy, investigators can determine keratocyte density in the corneal stroma in vivo. We and others have written automated algorithm to measure keratocyte density from human corneal confocal images. Such algorithms are only accurate if they exclude images of stromal nerve bundles (elongated objects) that would otherwise be counted as keratocytes. In this study we devised an algorithm to identify stromal nerve bundles and exclude them from measurements of keratocyte density. Nerve bundles were detected based on their size and aspect ratio, and were then subtracted from images by using a combination of morphology operations and direction calculations. The validity of nerve removal on measurements of keratocyte density was assessed. Keratocyte density was measured from confocal images of three normal human corneas in vivo by using our algorithm with nerve removal. After the same eyes underwent enucleation, density was measured manually from histologic sections. Keratocyte density was also measured from confocal images of 57 normal corneas in vivo (57 subjects) with and without nerve removal. In the three enucleated eyes, there was no significant difference between keratocyte density measured by automated counting with nerve removal and by histologic methods (P = 0.75). However, in the 57 normal corneas, use of the nerve-removal algorithm reduced estimates of density by 57.0±164.6 cells/mm 3 (mean±SD, p<0.038) in the anterior two-thirds of the stroma.

AB - With the advent of corneal confocal microscopy, investigators can determine keratocyte density in the corneal stroma in vivo. We and others have written automated algorithm to measure keratocyte density from human corneal confocal images. Such algorithms are only accurate if they exclude images of stromal nerve bundles (elongated objects) that would otherwise be counted as keratocytes. In this study we devised an algorithm to identify stromal nerve bundles and exclude them from measurements of keratocyte density. Nerve bundles were detected based on their size and aspect ratio, and were then subtracted from images by using a combination of morphology operations and direction calculations. The validity of nerve removal on measurements of keratocyte density was assessed. Keratocyte density was measured from confocal images of three normal human corneas in vivo by using our algorithm with nerve removal. After the same eyes underwent enucleation, density was measured manually from histologic sections. Keratocyte density was also measured from confocal images of 57 normal corneas in vivo (57 subjects) with and without nerve removal. In the three enucleated eyes, there was no significant difference between keratocyte density measured by automated counting with nerve removal and by histologic methods (P = 0.75). However, in the 57 normal corneas, use of the nerve-removal algorithm reduced estimates of density by 57.0±164.6 cells/mm 3 (mean±SD, p<0.038) in the anterior two-thirds of the stroma.

UR - http://www.scopus.com/inward/record.url?scp=0033688733&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033688733&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0033688733

VL - 3979

BT - Proceedings of SPIE - The International Society for Optical Engineering

PB - Society of Photo-Optical Instrumentation Engineers

ER -