TY - JOUR
T1 - Automated and clinical breast imaging reporting and data system density measures predict risk for screen-detected and interval cancers
T2 - A case-control study
AU - Kerlikowske, Karla
AU - Scott, Christopher G.
AU - Mahmoudzadeh, Amir P.
AU - Ma, Lin
AU - Winham, Stacey
AU - Jensen, Matthew R.
AU - Wu, Fang Fang
AU - Malkov, Serghei
AU - Pankratz, V. Shane
AU - Cummings, Steven R.
AU - Shepherd, John A.
AU - Brandt, Kathleen R.
AU - Miglioretti, Diana L.
AU - Vachon, Celine M.
N1 - Funding Information:
In part by grants R01 CA177150, P01 2CA154292, and R01 CA207085 from the National Institutes of Health, National Cancer Institute.
Funding Information:
Disclosures: Dr. Miglioretti reports grants from the National Institutes of Health during the conduct of the study, and personal and travel fees from Hologic outside the submitted work. Dr. Vachon reports grants from the National Cancer Institute during the conduct of the study and funding from Grail outside the submitted work. Authors not named here have disclosed no conflicts of interest. Disclosures can also be viewed at www.acponline.org/authors/icmje/ConflictOf InterestForms.do?msNum=M17-3008.
Funding Information:
Grant Support: In part by grants R01 CA177150, P01 2CA154292, and R01 CA207085 from the National Institutes of Health, National Cancer Institute.
Publisher Copyright:
© 2018 American College of Physicians.
PY - 2018/6/5
Y1 - 2018/6/5
N2 - Background: In 30 states, women who have had screening mammography are informed of their breast density on the basis of Breast Imaging Reporting and Data System (BI-RADS) density categories estimated subjectively by radiologists. Variation in these clinical categories across and within radiologists has led to discussion about whether automated BI-RADS density should be reported instead. Objective: To determine whether breast cancer risk and detection are similar for automated and clinical BI-RADS density measures. Design: Case-control. Setting: San Francisco Mammography Registry and Mayo Clinic. Participants: 1609 women with screen-detected cancer, 351 women with interval invasive cancer, and 4409 matched control participants. Measurements: Automated and clinical BI-RADS density assessed on digital mammography at 2 time points from September 2006 to October 2014, interval and screen-detected breast cancer risk, and mammography sensitivity. Results: Of women whose breast density was categorized by automated BI-RADS more than 6 months to 5 years before diagnosis, those with extremely dense breasts had a 5.65-fold higher interval cancer risk (95% CI, 3.33 to 9.60) and a 1.43-fold higher screen-detected risk (CI, 1.14 to 1.79) than those with scattered fibroglandular densities. Associations of interval and screendetected cancer with clinical BI-RADS density were similar to those with automated BI-RADS density, regardless of whether density was measured more than 6 months to less than 2 years or 2 to 5 years before diagnosis. Automated and clinical BI-RADS density measures had similar discriminatory accuracy, which was higher for interval than screen-detected cancer (c-statistics: 0.70 vs. 0.62 [P < 0.001] and 0.72 vs. 0.62 [P < 0.001], respectively). Mammography sensitivity was similar for automated and clinical BI-RADS categories: fatty, 93% versus 92%; scattered fibroglandular densities, 90% versus 90%; heterogeneously dense, 82% versus 78%; and extremely dense, 63% versus 64%, respectively. Limitation: Neither automated nor clinical BI-RADS density was assessed on tomosynthesis, an emerging breast screening method. Conclusion: Automated and clinical BI-RADS density similarly predict interval and screen-detected cancer risk, suggesting that either measure may be used to inform women of their breast density.
AB - Background: In 30 states, women who have had screening mammography are informed of their breast density on the basis of Breast Imaging Reporting and Data System (BI-RADS) density categories estimated subjectively by radiologists. Variation in these clinical categories across and within radiologists has led to discussion about whether automated BI-RADS density should be reported instead. Objective: To determine whether breast cancer risk and detection are similar for automated and clinical BI-RADS density measures. Design: Case-control. Setting: San Francisco Mammography Registry and Mayo Clinic. Participants: 1609 women with screen-detected cancer, 351 women with interval invasive cancer, and 4409 matched control participants. Measurements: Automated and clinical BI-RADS density assessed on digital mammography at 2 time points from September 2006 to October 2014, interval and screen-detected breast cancer risk, and mammography sensitivity. Results: Of women whose breast density was categorized by automated BI-RADS more than 6 months to 5 years before diagnosis, those with extremely dense breasts had a 5.65-fold higher interval cancer risk (95% CI, 3.33 to 9.60) and a 1.43-fold higher screen-detected risk (CI, 1.14 to 1.79) than those with scattered fibroglandular densities. Associations of interval and screendetected cancer with clinical BI-RADS density were similar to those with automated BI-RADS density, regardless of whether density was measured more than 6 months to less than 2 years or 2 to 5 years before diagnosis. Automated and clinical BI-RADS density measures had similar discriminatory accuracy, which was higher for interval than screen-detected cancer (c-statistics: 0.70 vs. 0.62 [P < 0.001] and 0.72 vs. 0.62 [P < 0.001], respectively). Mammography sensitivity was similar for automated and clinical BI-RADS categories: fatty, 93% versus 92%; scattered fibroglandular densities, 90% versus 90%; heterogeneously dense, 82% versus 78%; and extremely dense, 63% versus 64%, respectively. Limitation: Neither automated nor clinical BI-RADS density was assessed on tomosynthesis, an emerging breast screening method. Conclusion: Automated and clinical BI-RADS density similarly predict interval and screen-detected cancer risk, suggesting that either measure may be used to inform women of their breast density.
UR - http://www.scopus.com/inward/record.url?scp=85048504838&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85048504838&partnerID=8YFLogxK
U2 - 10.7326/M17-3008
DO - 10.7326/M17-3008
M3 - Article
C2 - 29710124
AN - SCOPUS:85048504838
SN - 0003-4819
VL - 168
SP - 757
EP - 765
JO - Annals of Internal Medicine
JF - Annals of Internal Medicine
IS - 11
ER -