An interactive eye-tracking system for measuring radiologists' visual fixations in volumetric CT images: Implementation and initial eye-tracking accuracy validation

Hao Gong, Scott S. Hsieh, David R. Holmes, David A. Cook, Akitoshi Inoue, David J. Bartlett, Francis Baffour, Hiroaki Takahashi, Shuai Leng, Lifeng Yu, Cynthia H. McCollough, Joel G. Fletcher

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: Eye-tracking approaches have been used to understand the visual search process in radiology. However, previous eye-tracking work in computer tomography (CT) has been limited largely to single cross-sectional images or video playback of the reconstructed volume, which do not accurately reflect radiologists' visual search activities and their interactivity with three-dimensional image data at a computer workstation (e.g., scroll, pan, and zoom) for visual evaluation of diagnostic imaging targets. We have developed a platform that integrates eye-tracking hardware with in-house-developed reader workstation software to allow monitoring of the visual search process and reader-image interactions in clinically relevant reader tasks. The purpose of this work is to validate the spatial accuracy of eye-tracking data using this platform for different eye-tracking data acquisition modes. Methods: An eye-tracker was integrated with a previously developed workstation designed for reader performance studies. The integrated system captured real-time eye movement and workstation events at 1000 Hz sampling frequency. The eye-tracker was operated either in head-stabilized mode or in free-movement mode. In head-stabilized mode, the reader positioned their head on a manufacturer-provided chinrest. In free-movement mode, a biofeedback tool emitted an audio cue when the head position was outside the data collection range (general biofeedback) or outside a narrower range of positions near the calibration position (strict biofeedback). Four radiologists and one resident were invited to participate in three studies to determine eye-tracking spatial accuracy under three constraint conditions: head-stabilized mode (i.e., with use of a chin rest), free movement with general biofeedback, and free movement with strict biofeedback. Study 1 evaluated the impact of head stabilization versus general or strict biofeedback using a cross-hair target prior to the integration of the eye-tracker with the image viewing workstation. In Study 2, after integration of the eye-tracker and reader workstation, readers were asked to fixate on targets that were randomly distributed within a volumetric digital phantom. In Study 3, readers used the integrated system to scroll through volumetric patient CT angiographic images while fixating on the centerline of designated blood vessels (from the left coronary artery to dorsalis pedis artery). Spatial accuracy was quantified as the offset between the center of the intended target and the detected fixation using units of image pixels and the degree of visual angle. Results: The three head position constraint conditions yielded comparable accuracy in the studies using digital phantoms. For Study 1 involving the digital crosshairs, the median ± the standard deviation of offset values among readers were 15.2 ± 7.0 image pixels with the chinrest, 14.2 ± 3.6 image pixels with strict biofeedback, and 19.1 ± 6.5 image pixels with general biofeedback. For Study 2 using the random dot phantom, the median ± standard deviation offset values were 16.7 ± 28.8 pixels with use of a chinrest, 16.5 ± 24.6 pixels using strict biofeedback, and 18.0 ± 22.4 pixels using general biofeedback, which translated to a visual angle of about 0.8° for all three conditions. We found no obvious association between eye-tracking accuracy and target size or view time. In Study 3 viewing patient images, use of the chinrest and strict biofeedback demonstrated comparable accuracy, while the use of general biofeedback demonstrated a slightly worse accuracy. The median ± standard deviation of offset values were 14.8 ± 11.4 pixels with use of a chinrest, 21.0 ± 16.2 pixels using strict biofeedback, and 29.7 ± 20.9 image pixels using general biofeedback. These corresponded to visual angles ranging from 0.7° to 1.3°. Conclusions: An integrated eye-tracker system to assess reader eye movement and interactive viewing in relation to imaging targets demonstrated reasonable spatial accuracy for assessment of visual fixation. The head-free movement condition with audio biofeedback performed similarly to head-stabilized mode.

Original languageEnglish (US)
Pages (from-to)6710-6723
Number of pages14
JournalMedical physics
Volume48
Issue number11
DOIs
StatePublished - Nov 2021

Keywords

  • biofeedback
  • computed tomography
  • eye tracking
  • observer performance