T1 - Alignment of dynamic cardiac PET images for correction of motion
AU - Turkington, Timothy G.
AU - Degrado, Timothy R.
AU - Hanson, Michael W.
AU - Edward Coleman, R.
N1 - Funding Information:
Manuscript received November 15, 1995; revised January 6, 1997. This work was supported in part by the NIH under Grant HL17670 and a research agreement with General Electric. The authors are with the Department of Radiology, Duke University Medical Center, Durham, NC 27710 USA. Publisher Item Identifier S 0018-9499(97)02798-6.
PY - 1997
Y1 - 1997
N2 - A technique was developed to align images from dynamic cardiac N-13 ammonia positron emission tomography (PET) scans. Inaccurate alignment of images from these scans stems from breathing, motion of the heart within the thorax, and overall motion of the patient (particularly during pharmacologie stress). The images from these scans represent changing distributions, from high blood pool concentrations to predominantly myocardial uptake, and are generally noisy. In this technique, templates are defined from a long, late frame (5-10 min). These templates include a myocardial template, which matches late frames, a blood pool template, which matches frames in which the left ventricle blood pool is dominant, and a modified blood pool template, which reduces the effect of activity in the right ventricle. The correlation function is used as the maximized parameter over shifts between each three-dimensional image frame and the appropriate template. The technique was tested on phantom, human, and animal data with myocardial defects. Phantom data showed the technique to be reliable to within one voxel (1.7 x 1.7 x 4.2 mm3 ), and motion which was apparent in human data was reduced significantly. Blood flow values measured from corrected data showed two traits: higher values, due to better matching regions of interest to images, and better fits, due to smoother time-activity curves.
AB - A technique was developed to align images from dynamic cardiac N-13 ammonia positron emission tomography (PET) scans. Inaccurate alignment of images from these scans stems from breathing, motion of the heart within the thorax, and overall motion of the patient (particularly during pharmacologie stress). The images from these scans represent changing distributions, from high blood pool concentrations to predominantly myocardial uptake, and are generally noisy. In this technique, templates are defined from a long, late frame (5-10 min). These templates include a myocardial template, which matches late frames, a blood pool template, which matches frames in which the left ventricle blood pool is dominant, and a modified blood pool template, which reduces the effect of activity in the right ventricle. The correlation function is used as the maximized parameter over shifts between each three-dimensional image frame and the appropriate template. The technique was tested on phantom, human, and animal data with myocardial defects. Phantom data showed the technique to be reliable to within one voxel (1.7 x 1.7 x 4.2 mm3 ), and motion which was apparent in human data was reduced significantly. Blood flow values measured from corrected data showed two traits: higher values, due to better matching regions of interest to images, and better fits, due to smoother time-activity curves.
UR - http://www.scopus.com/inward/record.url?scp=0031125559&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031125559&partnerID=8YFLogxK
U2 - 10.1109/23.568814
DO - 10.1109/23.568814
M3 - Article
AN - SCOPUS:0031125559
SN - 0018-9499
VL - 44
SP - 235
EP - 242
JO - IEEE Transactions on Nuclear Science
JF - IEEE Transactions on Nuclear Science
IS - 2
ER -