ALGEBRAIC RECONSTRUCTION OF SPATIAL DISTRIBUTIONS OF ACOUSTIC VELOCITIES IN TISSUE FROM THEIR TIME-OF-FLIGHT PROFILES.

James F Greenleaf, Steven A. Johnson, William F. Samayoa, Francis A. Duck

Research output: Chapter in Book/Report/Conference proceedingChapter

109 Citations (Scopus)

Abstract

Two-dimensional distributions of acoustic velocities were measured in transverse sections through intact isolated organs, using reconstruction techniques. Profiles of time-of-flight (TOF) of 10 MHz pulses through the specimen were obtained by rectilinearly scanning two opposing transducers along either side of the specimen in the plane of interest. The received pulses were digitized at a rate of one 8-bit sample-per-10 nanosec, for 512 samples and were analyzed with a computer algorithm which calculated the TOF of the pulse to within plus or minus 10 nanosec. Typically, 256 measurements of TOF were made in each profile scan for each of 37 angles of view separated by 5 degree . TOF's through tissue, normalized by TOF through water, were used to calculate velocity within the specimen, using an algebraic reconstruction technique (ART). Images obtained represented acoustic velocities in individual cross sections within the tissue specimen with a resolution of 64 by 64 elements ( less than 2 mm square). The disadvantage of TOF reconstruction is that transmission scanning is required. Advantages over B- and C-scan are discussed.

Original languageEnglish (US)
Title of host publicationAcoust Hologr
Pages71-90
Number of pages20
Volume6
StatePublished - 1975
EventInt Symp on Acoust Hologr and Imagaing, 6th, Proc - San Diego, CA, USA
Duration: Feb 4 1975Feb 7 1975

Other

OtherInt Symp on Acoust Hologr and Imagaing, 6th, Proc
CitySan Diego, CA, USA
Period2/4/752/7/75

Fingerprint

Acoustic wave velocity
Spatial distribution
Tissue
Scanning
Transducers
Water

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Greenleaf, J. F., Johnson, S. A., Samayoa, W. F., & Duck, F. A. (1975). ALGEBRAIC RECONSTRUCTION OF SPATIAL DISTRIBUTIONS OF ACOUSTIC VELOCITIES IN TISSUE FROM THEIR TIME-OF-FLIGHT PROFILES. In Acoust Hologr (Vol. 6, pp. 71-90)

ALGEBRAIC RECONSTRUCTION OF SPATIAL DISTRIBUTIONS OF ACOUSTIC VELOCITIES IN TISSUE FROM THEIR TIME-OF-FLIGHT PROFILES. / Greenleaf, James F; Johnson, Steven A.; Samayoa, William F.; Duck, Francis A.

Acoust Hologr. Vol. 6 1975. p. 71-90.

Research output: Chapter in Book/Report/Conference proceedingChapter

Greenleaf, JF, Johnson, SA, Samayoa, WF & Duck, FA 1975, ALGEBRAIC RECONSTRUCTION OF SPATIAL DISTRIBUTIONS OF ACOUSTIC VELOCITIES IN TISSUE FROM THEIR TIME-OF-FLIGHT PROFILES. in Acoust Hologr. vol. 6, pp. 71-90, Int Symp on Acoust Hologr and Imagaing, 6th, Proc, San Diego, CA, USA, 2/4/75.
Greenleaf, James F ; Johnson, Steven A. ; Samayoa, William F. ; Duck, Francis A. / ALGEBRAIC RECONSTRUCTION OF SPATIAL DISTRIBUTIONS OF ACOUSTIC VELOCITIES IN TISSUE FROM THEIR TIME-OF-FLIGHT PROFILES. Acoust Hologr. Vol. 6 1975. pp. 71-90
@inbook{f3c9c3414cc64503ace2a18fa6197319,
title = "ALGEBRAIC RECONSTRUCTION OF SPATIAL DISTRIBUTIONS OF ACOUSTIC VELOCITIES IN TISSUE FROM THEIR TIME-OF-FLIGHT PROFILES.",
abstract = "Two-dimensional distributions of acoustic velocities were measured in transverse sections through intact isolated organs, using reconstruction techniques. Profiles of time-of-flight (TOF) of 10 MHz pulses through the specimen were obtained by rectilinearly scanning two opposing transducers along either side of the specimen in the plane of interest. The received pulses were digitized at a rate of one 8-bit sample-per-10 nanosec, for 512 samples and were analyzed with a computer algorithm which calculated the TOF of the pulse to within plus or minus 10 nanosec. Typically, 256 measurements of TOF were made in each profile scan for each of 37 angles of view separated by 5 degree . TOF's through tissue, normalized by TOF through water, were used to calculate velocity within the specimen, using an algebraic reconstruction technique (ART). Images obtained represented acoustic velocities in individual cross sections within the tissue specimen with a resolution of 64 by 64 elements ( less than 2 mm square). The disadvantage of TOF reconstruction is that transmission scanning is required. Advantages over B- and C-scan are discussed.",
author = "Greenleaf, {James F} and Johnson, {Steven A.} and Samayoa, {William F.} and Duck, {Francis A.}",
year = "1975",
language = "English (US)",
volume = "6",
pages = "71--90",
booktitle = "Acoust Hologr",

}

TY - CHAP

T1 - ALGEBRAIC RECONSTRUCTION OF SPATIAL DISTRIBUTIONS OF ACOUSTIC VELOCITIES IN TISSUE FROM THEIR TIME-OF-FLIGHT PROFILES.

AU - Greenleaf, James F

AU - Johnson, Steven A.

AU - Samayoa, William F.

AU - Duck, Francis A.

PY - 1975

Y1 - 1975

N2 - Two-dimensional distributions of acoustic velocities were measured in transverse sections through intact isolated organs, using reconstruction techniques. Profiles of time-of-flight (TOF) of 10 MHz pulses through the specimen were obtained by rectilinearly scanning two opposing transducers along either side of the specimen in the plane of interest. The received pulses were digitized at a rate of one 8-bit sample-per-10 nanosec, for 512 samples and were analyzed with a computer algorithm which calculated the TOF of the pulse to within plus or minus 10 nanosec. Typically, 256 measurements of TOF were made in each profile scan for each of 37 angles of view separated by 5 degree . TOF's through tissue, normalized by TOF through water, were used to calculate velocity within the specimen, using an algebraic reconstruction technique (ART). Images obtained represented acoustic velocities in individual cross sections within the tissue specimen with a resolution of 64 by 64 elements ( less than 2 mm square). The disadvantage of TOF reconstruction is that transmission scanning is required. Advantages over B- and C-scan are discussed.

AB - Two-dimensional distributions of acoustic velocities were measured in transverse sections through intact isolated organs, using reconstruction techniques. Profiles of time-of-flight (TOF) of 10 MHz pulses through the specimen were obtained by rectilinearly scanning two opposing transducers along either side of the specimen in the plane of interest. The received pulses were digitized at a rate of one 8-bit sample-per-10 nanosec, for 512 samples and were analyzed with a computer algorithm which calculated the TOF of the pulse to within plus or minus 10 nanosec. Typically, 256 measurements of TOF were made in each profile scan for each of 37 angles of view separated by 5 degree . TOF's through tissue, normalized by TOF through water, were used to calculate velocity within the specimen, using an algebraic reconstruction technique (ART). Images obtained represented acoustic velocities in individual cross sections within the tissue specimen with a resolution of 64 by 64 elements ( less than 2 mm square). The disadvantage of TOF reconstruction is that transmission scanning is required. Advantages over B- and C-scan are discussed.

UR - http://www.scopus.com/inward/record.url?scp=0016624330&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0016624330&partnerID=8YFLogxK

M3 - Chapter

VL - 6

SP - 71

EP - 90

BT - Acoust Hologr

ER -