Adaptive technique for high-definition MR imaging of moving structures

Richard Lorne Ehman, J. P. Felmlee

Research output: Contribution to journalArticle

619 Citations (Scopus)

Abstract

An adaptive technique for measuring and correcting the effects of patient motion during magnetic resonance image acquistion was developed and tested. A set of algorithms that can reverse the effects of object displacements and phase shifts was used. These algorithms essentially transfer the frame of reference of the image reconstruction from the static frame of the imager couch to the moving 'visceral frame'. An accurate record of tissue motion during image acquisition is required. To achieve this, the authors used specially encoded 'navigator' echoes that are interleaved with the imaging sequence. Postprocessing of the navigator echo data provides a highly detailed record of the displacements and phase shifts that occur during imaging. Phantom studies demonstrated that the technique can directly correct image degradation caused by motion. In contrast to conventional artifact reduction techniques, such as ordered phase encoding and gradient moment nulling, this new method has a unique capacity to reduce motion unsharpness. Preliminary in vivo studies have demonstrated that the technique can markedly improve images degraded by voluntary motion and shows promise for addressing the problem of respiratory motion in thoracoabdominal imaging.

Original languageEnglish (US)
Pages (from-to)255-263
Number of pages9
JournalRadiology
Volume173
Issue number1
StatePublished - 1989

Fingerprint

Computer-Assisted Image Processing
Artifacts
Magnetic Resonance Spectroscopy

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Adaptive technique for high-definition MR imaging of moving structures. / Ehman, Richard Lorne; Felmlee, J. P.

In: Radiology, Vol. 173, No. 1, 1989, p. 255-263.

Research output: Contribution to journalArticle

@article{4160cbbab8ab4e2dabaf012bd2ec6c19,
title = "Adaptive technique for high-definition MR imaging of moving structures",
abstract = "An adaptive technique for measuring and correcting the effects of patient motion during magnetic resonance image acquistion was developed and tested. A set of algorithms that can reverse the effects of object displacements and phase shifts was used. These algorithms essentially transfer the frame of reference of the image reconstruction from the static frame of the imager couch to the moving 'visceral frame'. An accurate record of tissue motion during image acquisition is required. To achieve this, the authors used specially encoded 'navigator' echoes that are interleaved with the imaging sequence. Postprocessing of the navigator echo data provides a highly detailed record of the displacements and phase shifts that occur during imaging. Phantom studies demonstrated that the technique can directly correct image degradation caused by motion. In contrast to conventional artifact reduction techniques, such as ordered phase encoding and gradient moment nulling, this new method has a unique capacity to reduce motion unsharpness. Preliminary in vivo studies have demonstrated that the technique can markedly improve images degraded by voluntary motion and shows promise for addressing the problem of respiratory motion in thoracoabdominal imaging.",
author = "Ehman, {Richard Lorne} and Felmlee, {J. P.}",
year = "1989",
language = "English (US)",
volume = "173",
pages = "255--263",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "1",

}

TY - JOUR

T1 - Adaptive technique for high-definition MR imaging of moving structures

AU - Ehman, Richard Lorne

AU - Felmlee, J. P.

PY - 1989

Y1 - 1989

N2 - An adaptive technique for measuring and correcting the effects of patient motion during magnetic resonance image acquistion was developed and tested. A set of algorithms that can reverse the effects of object displacements and phase shifts was used. These algorithms essentially transfer the frame of reference of the image reconstruction from the static frame of the imager couch to the moving 'visceral frame'. An accurate record of tissue motion during image acquisition is required. To achieve this, the authors used specially encoded 'navigator' echoes that are interleaved with the imaging sequence. Postprocessing of the navigator echo data provides a highly detailed record of the displacements and phase shifts that occur during imaging. Phantom studies demonstrated that the technique can directly correct image degradation caused by motion. In contrast to conventional artifact reduction techniques, such as ordered phase encoding and gradient moment nulling, this new method has a unique capacity to reduce motion unsharpness. Preliminary in vivo studies have demonstrated that the technique can markedly improve images degraded by voluntary motion and shows promise for addressing the problem of respiratory motion in thoracoabdominal imaging.

AB - An adaptive technique for measuring and correcting the effects of patient motion during magnetic resonance image acquistion was developed and tested. A set of algorithms that can reverse the effects of object displacements and phase shifts was used. These algorithms essentially transfer the frame of reference of the image reconstruction from the static frame of the imager couch to the moving 'visceral frame'. An accurate record of tissue motion during image acquisition is required. To achieve this, the authors used specially encoded 'navigator' echoes that are interleaved with the imaging sequence. Postprocessing of the navigator echo data provides a highly detailed record of the displacements and phase shifts that occur during imaging. Phantom studies demonstrated that the technique can directly correct image degradation caused by motion. In contrast to conventional artifact reduction techniques, such as ordered phase encoding and gradient moment nulling, this new method has a unique capacity to reduce motion unsharpness. Preliminary in vivo studies have demonstrated that the technique can markedly improve images degraded by voluntary motion and shows promise for addressing the problem of respiratory motion in thoracoabdominal imaging.

UR - http://www.scopus.com/inward/record.url?scp=0024453449&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024453449&partnerID=8YFLogxK

M3 - Article

C2 - 2781017

AN - SCOPUS:0024453449

VL - 173

SP - 255

EP - 263

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 1

ER -