Accuracy of microvascular measurements obtained from micro-CT images

Timothy Kline, Mair Zamir, Erik L. Ritman

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Early changes in branching geometry of microvasculature and its associated impact on the perfusion distribution in diseases, especially those in which different branching generations are affected differently, require the ability to analyze intact vascular trees over a wide range of scales. Micro-CT offers an excellent framework to analyze the microvascular branching geometry. Such an analysis requires methods to be developed that can accurately characterize branching properties, such as branch diameter, length, branching angle, and branch interconnectivity of the microvasculature. The purpose of this article is to report the results of a study of two human intramyocardial coronary vascular tree casts in which the accuracy of micro-CT vascular imaging and its analysis are tested against measurements made through an optical microscope (used as the "gold-standard"). Methods related to image segmentation of the vascular lumen, vessel tree centerline extraction, individual branch segment measurement, and compensating for the non-ideal modulation transfer function of micro-CT scanners are presented. The extracted centerline accurately characterized the hierarchical structure of the vascular tree casts in terms of "parent-branch" relationships which allowed each interbranch segments' dimensions to be compared to the optical measurement method. The comparison results show a close to ideal 1:1 relationship for both length and diameter measurements made by the two methods. Combining the results from both specimens, the standard deviation of the difference between measurement methods was 19 μm for the measurement of interbranch segment diameters (ranging from 12 to 769 μm), and 172 μm for the measurement of interbranch segment lengths (ranging from 14 to 3252 μm). These results suggest that our micro-CT image analysis method can be used to characterize a vascular tree's hierarchical structure, and accurately measure interbranch segment lengths and diameters.

Original languageEnglish (US)
Pages (from-to)2851-2864
Number of pages14
JournalAnnals of Biomedical Engineering
Volume38
Issue number9
DOIs
StatePublished - Sep 2010

Fingerprint

Geometry
Optical transfer function
Image segmentation
Image analysis
Microscopes
Gold
Imaging techniques

Keywords

  • Centerline extraction
  • Hierarchical descriptor
  • Modulation transfer function
  • Point spread function
  • Vascular branching geometry
  • Vascular imaging
  • Vascular tree

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Accuracy of microvascular measurements obtained from micro-CT images. / Kline, Timothy; Zamir, Mair; Ritman, Erik L.

In: Annals of Biomedical Engineering, Vol. 38, No. 9, 09.2010, p. 2851-2864.

Research output: Contribution to journalArticle

Kline, Timothy ; Zamir, Mair ; Ritman, Erik L. / Accuracy of microvascular measurements obtained from micro-CT images. In: Annals of Biomedical Engineering. 2010 ; Vol. 38, No. 9. pp. 2851-2864.
@article{c5269dfb17d744a3a17ab07dfe31d70e,
title = "Accuracy of microvascular measurements obtained from micro-CT images",
abstract = "Early changes in branching geometry of microvasculature and its associated impact on the perfusion distribution in diseases, especially those in which different branching generations are affected differently, require the ability to analyze intact vascular trees over a wide range of scales. Micro-CT offers an excellent framework to analyze the microvascular branching geometry. Such an analysis requires methods to be developed that can accurately characterize branching properties, such as branch diameter, length, branching angle, and branch interconnectivity of the microvasculature. The purpose of this article is to report the results of a study of two human intramyocardial coronary vascular tree casts in which the accuracy of micro-CT vascular imaging and its analysis are tested against measurements made through an optical microscope (used as the {"}gold-standard{"}). Methods related to image segmentation of the vascular lumen, vessel tree centerline extraction, individual branch segment measurement, and compensating for the non-ideal modulation transfer function of micro-CT scanners are presented. The extracted centerline accurately characterized the hierarchical structure of the vascular tree casts in terms of {"}parent-branch{"} relationships which allowed each interbranch segments' dimensions to be compared to the optical measurement method. The comparison results show a close to ideal 1:1 relationship for both length and diameter measurements made by the two methods. Combining the results from both specimens, the standard deviation of the difference between measurement methods was 19 μm for the measurement of interbranch segment diameters (ranging from 12 to 769 μm), and 172 μm for the measurement of interbranch segment lengths (ranging from 14 to 3252 μm). These results suggest that our micro-CT image analysis method can be used to characterize a vascular tree's hierarchical structure, and accurately measure interbranch segment lengths and diameters.",
keywords = "Centerline extraction, Hierarchical descriptor, Modulation transfer function, Point spread function, Vascular branching geometry, Vascular imaging, Vascular tree",
author = "Timothy Kline and Mair Zamir and Ritman, {Erik L.}",
year = "2010",
month = "9",
doi = "10.1007/s10439-010-0058-7",
language = "English (US)",
volume = "38",
pages = "2851--2864",
journal = "Annals of Biomedical Engineering",
issn = "0090-6964",
publisher = "Springer Netherlands",
number = "9",

}

TY - JOUR

T1 - Accuracy of microvascular measurements obtained from micro-CT images

AU - Kline, Timothy

AU - Zamir, Mair

AU - Ritman, Erik L.

PY - 2010/9

Y1 - 2010/9

N2 - Early changes in branching geometry of microvasculature and its associated impact on the perfusion distribution in diseases, especially those in which different branching generations are affected differently, require the ability to analyze intact vascular trees over a wide range of scales. Micro-CT offers an excellent framework to analyze the microvascular branching geometry. Such an analysis requires methods to be developed that can accurately characterize branching properties, such as branch diameter, length, branching angle, and branch interconnectivity of the microvasculature. The purpose of this article is to report the results of a study of two human intramyocardial coronary vascular tree casts in which the accuracy of micro-CT vascular imaging and its analysis are tested against measurements made through an optical microscope (used as the "gold-standard"). Methods related to image segmentation of the vascular lumen, vessel tree centerline extraction, individual branch segment measurement, and compensating for the non-ideal modulation transfer function of micro-CT scanners are presented. The extracted centerline accurately characterized the hierarchical structure of the vascular tree casts in terms of "parent-branch" relationships which allowed each interbranch segments' dimensions to be compared to the optical measurement method. The comparison results show a close to ideal 1:1 relationship for both length and diameter measurements made by the two methods. Combining the results from both specimens, the standard deviation of the difference between measurement methods was 19 μm for the measurement of interbranch segment diameters (ranging from 12 to 769 μm), and 172 μm for the measurement of interbranch segment lengths (ranging from 14 to 3252 μm). These results suggest that our micro-CT image analysis method can be used to characterize a vascular tree's hierarchical structure, and accurately measure interbranch segment lengths and diameters.

AB - Early changes in branching geometry of microvasculature and its associated impact on the perfusion distribution in diseases, especially those in which different branching generations are affected differently, require the ability to analyze intact vascular trees over a wide range of scales. Micro-CT offers an excellent framework to analyze the microvascular branching geometry. Such an analysis requires methods to be developed that can accurately characterize branching properties, such as branch diameter, length, branching angle, and branch interconnectivity of the microvasculature. The purpose of this article is to report the results of a study of two human intramyocardial coronary vascular tree casts in which the accuracy of micro-CT vascular imaging and its analysis are tested against measurements made through an optical microscope (used as the "gold-standard"). Methods related to image segmentation of the vascular lumen, vessel tree centerline extraction, individual branch segment measurement, and compensating for the non-ideal modulation transfer function of micro-CT scanners are presented. The extracted centerline accurately characterized the hierarchical structure of the vascular tree casts in terms of "parent-branch" relationships which allowed each interbranch segments' dimensions to be compared to the optical measurement method. The comparison results show a close to ideal 1:1 relationship for both length and diameter measurements made by the two methods. Combining the results from both specimens, the standard deviation of the difference between measurement methods was 19 μm for the measurement of interbranch segment diameters (ranging from 12 to 769 μm), and 172 μm for the measurement of interbranch segment lengths (ranging from 14 to 3252 μm). These results suggest that our micro-CT image analysis method can be used to characterize a vascular tree's hierarchical structure, and accurately measure interbranch segment lengths and diameters.

KW - Centerline extraction

KW - Hierarchical descriptor

KW - Modulation transfer function

KW - Point spread function

KW - Vascular branching geometry

KW - Vascular imaging

KW - Vascular tree

UR - http://www.scopus.com/inward/record.url?scp=77956722141&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77956722141&partnerID=8YFLogxK

U2 - 10.1007/s10439-010-0058-7

DO - 10.1007/s10439-010-0058-7

M3 - Article

C2 - 20458628

AN - SCOPUS:77956722141

VL - 38

SP - 2851

EP - 2864

JO - Annals of Biomedical Engineering

JF - Annals of Biomedical Engineering

SN - 0090-6964

IS - 9

ER -