Aborted TAVR following aortic balloon valvuloplasty

Khaled D. Algarni, Kevin L. Greason, Rakesh M. Suri, Hector I Michelena, Joseph F. Maalouf

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

An 80-year-old man with symptomatic severe aortic valve stenosis was referred for transcatheter aortic valve replacement (TAVR) after balloon aortic valvuloplasty (BAV). The TAVR procedure was aborted because of identification of a mobile mass attached to the leading edge of the right cusp of the aortic valve on a transesophageal echocardiography. Surgical aortic valve replacement (SAVR) was performed and this mass was found to be an aortic cusp fenestration rupture that was caused by the BAV. doi: 10.1111/jocs.12451 (J Card Surg 2015;30:251-252)

Original languageEnglish (US)
Pages (from-to)251-252
Number of pages2
JournalJournal of Cardiac Surgery
Volume30
Issue number3
DOIs
StatePublished - Mar 1 2015

Fingerprint

Balloon Valvuloplasty
Aortic Valve
Transesophageal Echocardiography
Aortic Valve Stenosis
Surgical Instruments
Rupture
Transcatheter Aortic Valve Replacement

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Surgery

Cite this

Algarni, K. D., Greason, K. L., Suri, R. M., Michelena, H. I., & Maalouf, J. F. (2015). Aborted TAVR following aortic balloon valvuloplasty. Journal of Cardiac Surgery, 30(3), 251-252. https://doi.org/10.1111/jocs.12451

Aborted TAVR following aortic balloon valvuloplasty. / Algarni, Khaled D.; Greason, Kevin L.; Suri, Rakesh M.; Michelena, Hector I; Maalouf, Joseph F.

In: Journal of Cardiac Surgery, Vol. 30, No. 3, 01.03.2015, p. 251-252.

Research output: Contribution to journalArticle

Algarni, KD, Greason, KL, Suri, RM, Michelena, HI & Maalouf, JF 2015, 'Aborted TAVR following aortic balloon valvuloplasty', Journal of Cardiac Surgery, vol. 30, no. 3, pp. 251-252. https://doi.org/10.1111/jocs.12451
Algarni, Khaled D. ; Greason, Kevin L. ; Suri, Rakesh M. ; Michelena, Hector I ; Maalouf, Joseph F. / Aborted TAVR following aortic balloon valvuloplasty. In: Journal of Cardiac Surgery. 2015 ; Vol. 30, No. 3. pp. 251-252.
@article{75c9d283868b4bbf9c5e5a9de871f4c5,
title = "Aborted TAVR following aortic balloon valvuloplasty",
abstract = "An 80-year-old man with symptomatic severe aortic valve stenosis was referred for transcatheter aortic valve replacement (TAVR) after balloon aortic valvuloplasty (BAV). The TAVR procedure was aborted because of identification of a mobile mass attached to the leading edge of the right cusp of the aortic valve on a transesophageal echocardiography. Surgical aortic valve replacement (SAVR) was performed and this mass was found to be an aortic cusp fenestration rupture that was caused by the BAV. doi: 10.1111/jocs.12451 (J Card Surg 2015;30:251-252)",
author = "Algarni, {Khaled D.} and Greason, {Kevin L.} and Suri, {Rakesh M.} and Michelena, {Hector I} and Maalouf, {Joseph F.}",
year = "2015",
month = "3",
day = "1",
doi = "10.1111/jocs.12451",
language = "English (US)",
volume = "30",
pages = "251--252",
journal = "Journal of Cardiac Surgery",
issn = "0886-0440",
publisher = "Wiley-Blackwell",
number = "3",

}

TY - JOUR

T1 - Aborted TAVR following aortic balloon valvuloplasty

AU - Algarni, Khaled D.

AU - Greason, Kevin L.

AU - Suri, Rakesh M.

AU - Michelena, Hector I

AU - Maalouf, Joseph F.

PY - 2015/3/1

Y1 - 2015/3/1

N2 - An 80-year-old man with symptomatic severe aortic valve stenosis was referred for transcatheter aortic valve replacement (TAVR) after balloon aortic valvuloplasty (BAV). The TAVR procedure was aborted because of identification of a mobile mass attached to the leading edge of the right cusp of the aortic valve on a transesophageal echocardiography. Surgical aortic valve replacement (SAVR) was performed and this mass was found to be an aortic cusp fenestration rupture that was caused by the BAV. doi: 10.1111/jocs.12451 (J Card Surg 2015;30:251-252)

AB - An 80-year-old man with symptomatic severe aortic valve stenosis was referred for transcatheter aortic valve replacement (TAVR) after balloon aortic valvuloplasty (BAV). The TAVR procedure was aborted because of identification of a mobile mass attached to the leading edge of the right cusp of the aortic valve on a transesophageal echocardiography. Surgical aortic valve replacement (SAVR) was performed and this mass was found to be an aortic cusp fenestration rupture that was caused by the BAV. doi: 10.1111/jocs.12451 (J Card Surg 2015;30:251-252)

UR - http://www.scopus.com/inward/record.url?scp=84924111885&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84924111885&partnerID=8YFLogxK

U2 - 10.1111/jocs.12451

DO - 10.1111/jocs.12451

M3 - Article

C2 - 25202824

AN - SCOPUS:84924111885

VL - 30

SP - 251

EP - 252

JO - Journal of Cardiac Surgery

JF - Journal of Cardiac Surgery

SN - 0886-0440

IS - 3

ER -