Ability of near infrared spectroscopy to measure oxygenation in isolated upper extremity muscle compartments

Ashley L. Cole, Richard A. Herman, Jonathan B. Heimlich, Sahir Ahsan, Brett Freedman, Michael S. Shuler

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Purpose: Near infrared spectroscopy (NIRS), a noninvasive means for monitoring muscle oxygenation, may be useful in the diagnosis of acute compartment syndrome, a condition characterized by poor tissue perfusion. This study used the decrease in muscle oxygenation caused by exercise to investigate the ability of anatomic placement of NIRS sensor pads over compartments of the forearm to isolate perfusion values of a specific compartment. Methods: We recruited 63 uninjured volunteers from a private clinic-based setting and placed NIRS sensor pads over the dorsal, volar, and mobile wad compartments of 1 forearm. A total of 49 participants also had the contralateral forearm monitored, which served as an internal control. Participants performed a series of 3 exercises designed to sequentially activate the muscles of each compartment. A washout period separated each exercise to allow perfusion to return to baseline. We compared NIRS values of each compartment recorded during muscle contraction with baseline values. Results: Mean NIRS values decreased significantly from baseline during muscle contraction for all compartments, whereas mean NIRS values of muscle compartments that remained at rest showed little or no change. We observed no changes in NIRS values of the contralateral arm, which remained at rest during the entire data collection period. Conclusions: Although lack of an existing method for quantifying muscle perfusion precludes validation of this technique against a reference standard, this study suggests that NIRS can provide oxygenation values that are both sensitive and specific to muscle compartments of the forearm. Future studies should investigate NIRS among patients with upper extremity injuries. Type of study/level of evidence: Diagnostic III.

Original languageEnglish (US)
Pages (from-to)297-302
Number of pages6
JournalJournal of Hand Surgery
Volume37
Issue number2
DOIs
StatePublished - Feb 1 2012
Externally publishedYes

Fingerprint

Near-Infrared Spectroscopy
Upper Extremity
Muscles
Forearm
Perfusion
Exercise
Muscle Contraction
Compartment Syndromes
Volunteers
Arm
Wounds and Injuries

Keywords

  • Acute compartment syndrome
  • compartment syndrome
  • muscle perfusion
  • near infrared spectroscopy

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Cite this

Ability of near infrared spectroscopy to measure oxygenation in isolated upper extremity muscle compartments. / Cole, Ashley L.; Herman, Richard A.; Heimlich, Jonathan B.; Ahsan, Sahir; Freedman, Brett; Shuler, Michael S.

In: Journal of Hand Surgery, Vol. 37, No. 2, 01.02.2012, p. 297-302.

Research output: Contribution to journalArticle

Cole, Ashley L. ; Herman, Richard A. ; Heimlich, Jonathan B. ; Ahsan, Sahir ; Freedman, Brett ; Shuler, Michael S. / Ability of near infrared spectroscopy to measure oxygenation in isolated upper extremity muscle compartments. In: Journal of Hand Surgery. 2012 ; Vol. 37, No. 2. pp. 297-302.
@article{b8a686ac543545adbe606acb12af6987,
title = "Ability of near infrared spectroscopy to measure oxygenation in isolated upper extremity muscle compartments",
abstract = "Purpose: Near infrared spectroscopy (NIRS), a noninvasive means for monitoring muscle oxygenation, may be useful in the diagnosis of acute compartment syndrome, a condition characterized by poor tissue perfusion. This study used the decrease in muscle oxygenation caused by exercise to investigate the ability of anatomic placement of NIRS sensor pads over compartments of the forearm to isolate perfusion values of a specific compartment. Methods: We recruited 63 uninjured volunteers from a private clinic-based setting and placed NIRS sensor pads over the dorsal, volar, and mobile wad compartments of 1 forearm. A total of 49 participants also had the contralateral forearm monitored, which served as an internal control. Participants performed a series of 3 exercises designed to sequentially activate the muscles of each compartment. A washout period separated each exercise to allow perfusion to return to baseline. We compared NIRS values of each compartment recorded during muscle contraction with baseline values. Results: Mean NIRS values decreased significantly from baseline during muscle contraction for all compartments, whereas mean NIRS values of muscle compartments that remained at rest showed little or no change. We observed no changes in NIRS values of the contralateral arm, which remained at rest during the entire data collection period. Conclusions: Although lack of an existing method for quantifying muscle perfusion precludes validation of this technique against a reference standard, this study suggests that NIRS can provide oxygenation values that are both sensitive and specific to muscle compartments of the forearm. Future studies should investigate NIRS among patients with upper extremity injuries. Type of study/level of evidence: Diagnostic III.",
keywords = "Acute compartment syndrome, compartment syndrome, muscle perfusion, near infrared spectroscopy",
author = "Cole, {Ashley L.} and Herman, {Richard A.} and Heimlich, {Jonathan B.} and Sahir Ahsan and Brett Freedman and Shuler, {Michael S.}",
year = "2012",
month = "2",
day = "1",
doi = "10.1016/j.jhsa.2011.10.037",
language = "English (US)",
volume = "37",
pages = "297--302",
journal = "Journal of Hand Surgery",
issn = "0266-7681",
publisher = "W.B. Saunders Ltd",
number = "2",

}

TY - JOUR

T1 - Ability of near infrared spectroscopy to measure oxygenation in isolated upper extremity muscle compartments

AU - Cole, Ashley L.

AU - Herman, Richard A.

AU - Heimlich, Jonathan B.

AU - Ahsan, Sahir

AU - Freedman, Brett

AU - Shuler, Michael S.

PY - 2012/2/1

Y1 - 2012/2/1

N2 - Purpose: Near infrared spectroscopy (NIRS), a noninvasive means for monitoring muscle oxygenation, may be useful in the diagnosis of acute compartment syndrome, a condition characterized by poor tissue perfusion. This study used the decrease in muscle oxygenation caused by exercise to investigate the ability of anatomic placement of NIRS sensor pads over compartments of the forearm to isolate perfusion values of a specific compartment. Methods: We recruited 63 uninjured volunteers from a private clinic-based setting and placed NIRS sensor pads over the dorsal, volar, and mobile wad compartments of 1 forearm. A total of 49 participants also had the contralateral forearm monitored, which served as an internal control. Participants performed a series of 3 exercises designed to sequentially activate the muscles of each compartment. A washout period separated each exercise to allow perfusion to return to baseline. We compared NIRS values of each compartment recorded during muscle contraction with baseline values. Results: Mean NIRS values decreased significantly from baseline during muscle contraction for all compartments, whereas mean NIRS values of muscle compartments that remained at rest showed little or no change. We observed no changes in NIRS values of the contralateral arm, which remained at rest during the entire data collection period. Conclusions: Although lack of an existing method for quantifying muscle perfusion precludes validation of this technique against a reference standard, this study suggests that NIRS can provide oxygenation values that are both sensitive and specific to muscle compartments of the forearm. Future studies should investigate NIRS among patients with upper extremity injuries. Type of study/level of evidence: Diagnostic III.

AB - Purpose: Near infrared spectroscopy (NIRS), a noninvasive means for monitoring muscle oxygenation, may be useful in the diagnosis of acute compartment syndrome, a condition characterized by poor tissue perfusion. This study used the decrease in muscle oxygenation caused by exercise to investigate the ability of anatomic placement of NIRS sensor pads over compartments of the forearm to isolate perfusion values of a specific compartment. Methods: We recruited 63 uninjured volunteers from a private clinic-based setting and placed NIRS sensor pads over the dorsal, volar, and mobile wad compartments of 1 forearm. A total of 49 participants also had the contralateral forearm monitored, which served as an internal control. Participants performed a series of 3 exercises designed to sequentially activate the muscles of each compartment. A washout period separated each exercise to allow perfusion to return to baseline. We compared NIRS values of each compartment recorded during muscle contraction with baseline values. Results: Mean NIRS values decreased significantly from baseline during muscle contraction for all compartments, whereas mean NIRS values of muscle compartments that remained at rest showed little or no change. We observed no changes in NIRS values of the contralateral arm, which remained at rest during the entire data collection period. Conclusions: Although lack of an existing method for quantifying muscle perfusion precludes validation of this technique against a reference standard, this study suggests that NIRS can provide oxygenation values that are both sensitive and specific to muscle compartments of the forearm. Future studies should investigate NIRS among patients with upper extremity injuries. Type of study/level of evidence: Diagnostic III.

KW - Acute compartment syndrome

KW - compartment syndrome

KW - muscle perfusion

KW - near infrared spectroscopy

UR - http://www.scopus.com/inward/record.url?scp=84856254435&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84856254435&partnerID=8YFLogxK

U2 - 10.1016/j.jhsa.2011.10.037

DO - 10.1016/j.jhsa.2011.10.037

M3 - Article

C2 - 22189186

AN - SCOPUS:84856254435

VL - 37

SP - 297

EP - 302

JO - Journal of Hand Surgery

JF - Journal of Hand Surgery

SN - 0266-7681

IS - 2

ER -