A progressive gradient moment nulling design technique

James Pipe, Thomas L. Chenevert

Research output: Contribution to journalArticle

26 Citations (Scopus)

Abstract

A method is presented for designing motion‐compensated gradients in a progressive manner. The method is easily applicable to many types of waveforms, and can compensate for any order of motion. It can be implemented graphically or numerically. Underlying theory and examples of its application are provided. © 1991 Academic Press, Inc.

Original languageEnglish (US)
Pages (from-to)175-179
Number of pages5
JournalMagnetic Resonance in Medicine
Volume19
Issue number1
DOIs
StatePublished - Jan 1 1991
Externally publishedYes

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

A progressive gradient moment nulling design technique. / Pipe, James; Chenevert, Thomas L.

In: Magnetic Resonance in Medicine, Vol. 19, No. 1, 01.01.1991, p. 175-179.

Research output: Contribution to journalArticle

Pipe, James ; Chenevert, Thomas L. / A progressive gradient moment nulling design technique. In: Magnetic Resonance in Medicine. 1991 ; Vol. 19, No. 1. pp. 175-179.
@article{a007995d133d4a619b49e10170c829dc,
title = "A progressive gradient moment nulling design technique",
abstract = "A method is presented for designing motion‐compensated gradients in a progressive manner. The method is easily applicable to many types of waveforms, and can compensate for any order of motion. It can be implemented graphically or numerically. Underlying theory and examples of its application are provided. {\circledC} 1991 Academic Press, Inc.",
author = "James Pipe and Chenevert, {Thomas L.}",
year = "1991",
month = "1",
day = "1",
doi = "10.1002/mrm.1910190116",
language = "English (US)",
volume = "19",
pages = "175--179",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - A progressive gradient moment nulling design technique

AU - Pipe, James

AU - Chenevert, Thomas L.

PY - 1991/1/1

Y1 - 1991/1/1

N2 - A method is presented for designing motion‐compensated gradients in a progressive manner. The method is easily applicable to many types of waveforms, and can compensate for any order of motion. It can be implemented graphically or numerically. Underlying theory and examples of its application are provided. © 1991 Academic Press, Inc.

AB - A method is presented for designing motion‐compensated gradients in a progressive manner. The method is easily applicable to many types of waveforms, and can compensate for any order of motion. It can be implemented graphically or numerically. Underlying theory and examples of its application are provided. © 1991 Academic Press, Inc.

UR - http://www.scopus.com/inward/record.url?scp=0025778501&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025778501&partnerID=8YFLogxK

U2 - 10.1002/mrm.1910190116

DO - 10.1002/mrm.1910190116

M3 - Article

C2 - 2046531

AN - SCOPUS:0025778501

VL - 19

SP - 175

EP - 179

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 1

ER -