Abstract

In order to move the finger the tendon force must overcome the gliding resistance of the tendon as well as the forces to move the joints, finger inertias, and external load. These sources, combined, make up the work of flexion (WOF) which has been experimentally used to evaluate the finger function. In this study, we have designed a new device, which can measure the forces at the proximal and distal end of the tendon during finger flexion, so that gliding resistance can be isolated from the WOF. Two index fingers from a pair of human cadaver hands were used for testing this device. Preliminary data showed that internal resistance occupied about 10% of WOF with an intact tendon. However, after tendon repair, the gliding resistance increased 31% of WOF for a modified Kessler repair and 50% of WOF for a Becker repair compared to intact tendon. We simulated joint stiffness by injection of saline solution into the proximal interphalangeal joint. This increased the overall WOF but not the gliding resistance. We believe that this testing device provides a useful tool to evaluate finger function after tendon repair in an experimental model.

Original languageEnglish (US)
Pages (from-to)295-299
Number of pages5
JournalJournal of Biomechanics
Volume36
Issue number2
DOIs
StatePublished - Feb 1 2003

Fingerprint

Tendons
Fingers
Equipment and Supplies
Testing
Repair
Joints
Finger Joint
Cadaver
Sodium Chloride
Theoretical Models
Hand
Stiffness
Injections

Keywords

  • Flexor tendon
  • Resistance
  • Tendon repair
  • Work of flexion

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

A new testing device for measuring gliding resistance and work of flexion in a digit. / Zhao, Chunfeng D; Amadio, Peter C; Berglund, Lawrence; Zobitz, Mark E.; An, Kai N.

In: Journal of Biomechanics, Vol. 36, No. 2, 01.02.2003, p. 295-299.

Research output: Contribution to journalArticle

Zhao, Chunfeng D ; Amadio, Peter C ; Berglund, Lawrence ; Zobitz, Mark E. ; An, Kai N. / A new testing device for measuring gliding resistance and work of flexion in a digit. In: Journal of Biomechanics. 2003 ; Vol. 36, No. 2. pp. 295-299.
@article{b17667833e95485fa5f670d046351315,
title = "A new testing device for measuring gliding resistance and work of flexion in a digit",
abstract = "In order to move the finger the tendon force must overcome the gliding resistance of the tendon as well as the forces to move the joints, finger inertias, and external load. These sources, combined, make up the work of flexion (WOF) which has been experimentally used to evaluate the finger function. In this study, we have designed a new device, which can measure the forces at the proximal and distal end of the tendon during finger flexion, so that gliding resistance can be isolated from the WOF. Two index fingers from a pair of human cadaver hands were used for testing this device. Preliminary data showed that internal resistance occupied about 10{\%} of WOF with an intact tendon. However, after tendon repair, the gliding resistance increased 31{\%} of WOF for a modified Kessler repair and 50{\%} of WOF for a Becker repair compared to intact tendon. We simulated joint stiffness by injection of saline solution into the proximal interphalangeal joint. This increased the overall WOF but not the gliding resistance. We believe that this testing device provides a useful tool to evaluate finger function after tendon repair in an experimental model.",
keywords = "Flexor tendon, Resistance, Tendon repair, Work of flexion",
author = "Zhao, {Chunfeng D} and Amadio, {Peter C} and Lawrence Berglund and Zobitz, {Mark E.} and An, {Kai N.}",
year = "2003",
month = "2",
day = "1",
doi = "10.1016/S0021-9290(02)00300-7",
language = "English (US)",
volume = "36",
pages = "295--299",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Limited",
number = "2",

}

TY - JOUR

T1 - A new testing device for measuring gliding resistance and work of flexion in a digit

AU - Zhao, Chunfeng D

AU - Amadio, Peter C

AU - Berglund, Lawrence

AU - Zobitz, Mark E.

AU - An, Kai N.

PY - 2003/2/1

Y1 - 2003/2/1

N2 - In order to move the finger the tendon force must overcome the gliding resistance of the tendon as well as the forces to move the joints, finger inertias, and external load. These sources, combined, make up the work of flexion (WOF) which has been experimentally used to evaluate the finger function. In this study, we have designed a new device, which can measure the forces at the proximal and distal end of the tendon during finger flexion, so that gliding resistance can be isolated from the WOF. Two index fingers from a pair of human cadaver hands were used for testing this device. Preliminary data showed that internal resistance occupied about 10% of WOF with an intact tendon. However, after tendon repair, the gliding resistance increased 31% of WOF for a modified Kessler repair and 50% of WOF for a Becker repair compared to intact tendon. We simulated joint stiffness by injection of saline solution into the proximal interphalangeal joint. This increased the overall WOF but not the gliding resistance. We believe that this testing device provides a useful tool to evaluate finger function after tendon repair in an experimental model.

AB - In order to move the finger the tendon force must overcome the gliding resistance of the tendon as well as the forces to move the joints, finger inertias, and external load. These sources, combined, make up the work of flexion (WOF) which has been experimentally used to evaluate the finger function. In this study, we have designed a new device, which can measure the forces at the proximal and distal end of the tendon during finger flexion, so that gliding resistance can be isolated from the WOF. Two index fingers from a pair of human cadaver hands were used for testing this device. Preliminary data showed that internal resistance occupied about 10% of WOF with an intact tendon. However, after tendon repair, the gliding resistance increased 31% of WOF for a modified Kessler repair and 50% of WOF for a Becker repair compared to intact tendon. We simulated joint stiffness by injection of saline solution into the proximal interphalangeal joint. This increased the overall WOF but not the gliding resistance. We believe that this testing device provides a useful tool to evaluate finger function after tendon repair in an experimental model.

KW - Flexor tendon

KW - Resistance

KW - Tendon repair

KW - Work of flexion

UR - http://www.scopus.com/inward/record.url?scp=12244309487&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=12244309487&partnerID=8YFLogxK

U2 - 10.1016/S0021-9290(02)00300-7

DO - 10.1016/S0021-9290(02)00300-7

M3 - Article

C2 - 12547370

AN - SCOPUS:12244309487

VL - 36

SP - 295

EP - 299

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290

IS - 2

ER -