A new data consistency condition for fan-beam projection data

Guang Hong Chen, Shuai Leng

Research output: Contribution to journalArticle

34 Citations (Scopus)

Abstract

The sum of all attenuation data acquired in one view of parallel-beam projections is a view angle independent constant. This fact is known as a data consistency condition on the two-dimensional Radon transforms. It plays an important role in tomographic image reconstruction and artifact correction. In this paper, a novel fan-beam data consistency condition (FDCC) is derived and presented. Using the FDCC, individual projection data in one view of fan-beam projections can be estimated from filtering all other projection data measured from different view angles. Numerical simulations are performed to validate the new FDCC in correcting ring artifacts caused by malfunctioning detector cells.

Original languageEnglish (US)
Pages (from-to)961-967
Number of pages7
JournalMedical Physics
Volume32
Issue number4
DOIs
StatePublished - Apr 2005
Externally publishedYes

Fingerprint

Artifacts
Radon
Computer-Assisted Image Processing

Keywords

  • Artifacts
  • Fan-beam

ASJC Scopus subject areas

  • Biophysics

Cite this

A new data consistency condition for fan-beam projection data. / Chen, Guang Hong; Leng, Shuai.

In: Medical Physics, Vol. 32, No. 4, 04.2005, p. 961-967.

Research output: Contribution to journalArticle

Chen, Guang Hong ; Leng, Shuai. / A new data consistency condition for fan-beam projection data. In: Medical Physics. 2005 ; Vol. 32, No. 4. pp. 961-967.
@article{13880dd7637141888a776e93ae0b514f,
title = "A new data consistency condition for fan-beam projection data",
abstract = "The sum of all attenuation data acquired in one view of parallel-beam projections is a view angle independent constant. This fact is known as a data consistency condition on the two-dimensional Radon transforms. It plays an important role in tomographic image reconstruction and artifact correction. In this paper, a novel fan-beam data consistency condition (FDCC) is derived and presented. Using the FDCC, individual projection data in one view of fan-beam projections can be estimated from filtering all other projection data measured from different view angles. Numerical simulations are performed to validate the new FDCC in correcting ring artifacts caused by malfunctioning detector cells.",
keywords = "Artifacts, Fan-beam",
author = "Chen, {Guang Hong} and Shuai Leng",
year = "2005",
month = "4",
doi = "10.1118/1.1861395",
language = "English (US)",
volume = "32",
pages = "961--967",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "4",

}

TY - JOUR

T1 - A new data consistency condition for fan-beam projection data

AU - Chen, Guang Hong

AU - Leng, Shuai

PY - 2005/4

Y1 - 2005/4

N2 - The sum of all attenuation data acquired in one view of parallel-beam projections is a view angle independent constant. This fact is known as a data consistency condition on the two-dimensional Radon transforms. It plays an important role in tomographic image reconstruction and artifact correction. In this paper, a novel fan-beam data consistency condition (FDCC) is derived and presented. Using the FDCC, individual projection data in one view of fan-beam projections can be estimated from filtering all other projection data measured from different view angles. Numerical simulations are performed to validate the new FDCC in correcting ring artifacts caused by malfunctioning detector cells.

AB - The sum of all attenuation data acquired in one view of parallel-beam projections is a view angle independent constant. This fact is known as a data consistency condition on the two-dimensional Radon transforms. It plays an important role in tomographic image reconstruction and artifact correction. In this paper, a novel fan-beam data consistency condition (FDCC) is derived and presented. Using the FDCC, individual projection data in one view of fan-beam projections can be estimated from filtering all other projection data measured from different view angles. Numerical simulations are performed to validate the new FDCC in correcting ring artifacts caused by malfunctioning detector cells.

KW - Artifacts

KW - Fan-beam

UR - http://www.scopus.com/inward/record.url?scp=17844390166&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=17844390166&partnerID=8YFLogxK

U2 - 10.1118/1.1861395

DO - 10.1118/1.1861395

M3 - Article

C2 - 15895579

AN - SCOPUS:17844390166

VL - 32

SP - 961

EP - 967

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 4

ER -