A modified saturation-recovery approximation for multiple spin-echo pulse sequences

Research output: Contribution to journalArticle

29 Citations (Scopus)

Abstract

In equations describing multiple spin-echo pulse sequences, the T1 dependence is often approximated by a saturation-recovery expression, which is valid only when the repetition time T(R) is much greater than the time required for the echoes. A slight modification of this approximation greatly increases its accuracy for small T(R) values.

Original languageEnglish (US)
Pages (from-to)132-134
Number of pages3
JournalMagnetic Resonance in Medicine
Volume3
Issue number1
StatePublished - 1986
Externally publishedYes

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

A modified saturation-recovery approximation for multiple spin-echo pulse sequences. / Lee, J. N.; Riederer, Stephen J.

In: Magnetic Resonance in Medicine, Vol. 3, No. 1, 1986, p. 132-134.

Research output: Contribution to journalArticle

@article{0502062f315848bbb497c01198bcd210,
title = "A modified saturation-recovery approximation for multiple spin-echo pulse sequences",
abstract = "In equations describing multiple spin-echo pulse sequences, the T1 dependence is often approximated by a saturation-recovery expression, which is valid only when the repetition time T(R) is much greater than the time required for the echoes. A slight modification of this approximation greatly increases its accuracy for small T(R) values.",
author = "Lee, {J. N.} and Riederer, {Stephen J}",
year = "1986",
language = "English (US)",
volume = "3",
pages = "132--134",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - A modified saturation-recovery approximation for multiple spin-echo pulse sequences

AU - Lee, J. N.

AU - Riederer, Stephen J

PY - 1986

Y1 - 1986

N2 - In equations describing multiple spin-echo pulse sequences, the T1 dependence is often approximated by a saturation-recovery expression, which is valid only when the repetition time T(R) is much greater than the time required for the echoes. A slight modification of this approximation greatly increases its accuracy for small T(R) values.

AB - In equations describing multiple spin-echo pulse sequences, the T1 dependence is often approximated by a saturation-recovery expression, which is valid only when the repetition time T(R) is much greater than the time required for the echoes. A slight modification of this approximation greatly increases its accuracy for small T(R) values.

UR - http://www.scopus.com/inward/record.url?scp=0022644517&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022644517&partnerID=8YFLogxK

M3 - Article

VL - 3

SP - 132

EP - 134

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 1

ER -