A high frame-rate and low-cost Elastography system by generating shear waves through continuous vibration of the ultrasound transducer

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Ultrasound shear wave elastography (SWE) utilizes the propagation of induced shear waves to characterize the shear modulus of soft tissue. Many methods rely on an acoustic radiation force (ARF) push beam to generate shear waves. However, specialized hardware is required to generate the push beams, and the thermal stress that is placed upon the ultrasound system, transducer, and tissue by the push beams currently limits the frame-rate to about 1 Hz. This paper presents Probe Oscillation Shear Elastography (PROSE) as an alternative method to measure tissue elasticity, by generating shear waves using a continuous mechanical vibration of an ultrasound transducer, while simultaneously detecting motion with the same transducer under pulse-echo mode. Motion of the transducer during detection produces a compression strain artifact that is coupled with the observed shear waves. A novel symmetric sampling scheme is proposed such that pulse-echo detection events are acquired when the ultrasound transducer returns to the same physical position, allowing the shear waves to be decoupled from the compression artifact. Full field-of-view (FOV) two-dimensional (2D) shear wave speed (SWS) images were obtained by applying a local frequency estimation (LFE) method, capable of generating a 2D map from a single frame of shear wave motion, allowing for an imaging frame rate comparable to the vibration frequency. PROSE was able to produce smooth and accurate shear wave images from three homogeneous phantoms with different moduli, with an effective frame rate of 300Hz. An inclusion phantom study showed that increased vibration frequencies improved the accuracy of inclusion imaging, and allowed targets as small as 6.5 mm to be resolved with good contrast (contrast-to-noise ratio ≥19 dB) between the target and background.

Original languageEnglish (US)
Title of host publication2015 IEEE International Ultrasonics Symposium, IUS 2015
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Print)9781479981823
DOIs
StatePublished - Nov 13 2015
EventIEEE International Ultrasonics Symposium, IUS 2015 - Taipei, Taiwan, Province of China
Duration: Oct 21 2015Oct 24 2015

Other

OtherIEEE International Ultrasonics Symposium, IUS 2015
CountryTaiwan, Province of China
CityTaipei
Period10/21/1510/24/15

Fingerprint

S waves
transducers
vibration
shear
artifacts
echoes
inclusions
oscillations
probes
thermal stresses
pulses
sound waves
field of view
hardware
elastic properties
sampling
propagation

Keywords

  • Mechanical vibration
  • shear wave
  • ultrasound elastography

ASJC Scopus subject areas

  • Acoustics and Ultrasonics

Cite this

Mellema, D. C., Song, P., Manduca, A., Urban, M. W., Kinnick, R. R., Greenleaf, J. F., & Chen, S. D. (2015). A high frame-rate and low-cost Elastography system by generating shear waves through continuous vibration of the ultrasound transducer. In 2015 IEEE International Ultrasonics Symposium, IUS 2015 [7329311] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ULTSYM.2015.0203

A high frame-rate and low-cost Elastography system by generating shear waves through continuous vibration of the ultrasound transducer. / Mellema, Daniel C.; Song, Pengfei; Manduca, Armando; Urban, Matthew W; Kinnick, Randall R.; Greenleaf, James F; Chen, Shigao D.

2015 IEEE International Ultrasonics Symposium, IUS 2015. Institute of Electrical and Electronics Engineers Inc., 2015. 7329311.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Mellema, DC, Song, P, Manduca, A, Urban, MW, Kinnick, RR, Greenleaf, JF & Chen, SD 2015, A high frame-rate and low-cost Elastography system by generating shear waves through continuous vibration of the ultrasound transducer. in 2015 IEEE International Ultrasonics Symposium, IUS 2015., 7329311, Institute of Electrical and Electronics Engineers Inc., IEEE International Ultrasonics Symposium, IUS 2015, Taipei, Taiwan, Province of China, 10/21/15. https://doi.org/10.1109/ULTSYM.2015.0203
Mellema DC, Song P, Manduca A, Urban MW, Kinnick RR, Greenleaf JF et al. A high frame-rate and low-cost Elastography system by generating shear waves through continuous vibration of the ultrasound transducer. In 2015 IEEE International Ultrasonics Symposium, IUS 2015. Institute of Electrical and Electronics Engineers Inc. 2015. 7329311 https://doi.org/10.1109/ULTSYM.2015.0203
Mellema, Daniel C. ; Song, Pengfei ; Manduca, Armando ; Urban, Matthew W ; Kinnick, Randall R. ; Greenleaf, James F ; Chen, Shigao D. / A high frame-rate and low-cost Elastography system by generating shear waves through continuous vibration of the ultrasound transducer. 2015 IEEE International Ultrasonics Symposium, IUS 2015. Institute of Electrical and Electronics Engineers Inc., 2015.
@inproceedings{245df71fa2484e22906d88e12a0f435a,
title = "A high frame-rate and low-cost Elastography system by generating shear waves through continuous vibration of the ultrasound transducer",
abstract = "Ultrasound shear wave elastography (SWE) utilizes the propagation of induced shear waves to characterize the shear modulus of soft tissue. Many methods rely on an acoustic radiation force (ARF) push beam to generate shear waves. However, specialized hardware is required to generate the push beams, and the thermal stress that is placed upon the ultrasound system, transducer, and tissue by the push beams currently limits the frame-rate to about 1 Hz. This paper presents Probe Oscillation Shear Elastography (PROSE) as an alternative method to measure tissue elasticity, by generating shear waves using a continuous mechanical vibration of an ultrasound transducer, while simultaneously detecting motion with the same transducer under pulse-echo mode. Motion of the transducer during detection produces a compression strain artifact that is coupled with the observed shear waves. A novel symmetric sampling scheme is proposed such that pulse-echo detection events are acquired when the ultrasound transducer returns to the same physical position, allowing the shear waves to be decoupled from the compression artifact. Full field-of-view (FOV) two-dimensional (2D) shear wave speed (SWS) images were obtained by applying a local frequency estimation (LFE) method, capable of generating a 2D map from a single frame of shear wave motion, allowing for an imaging frame rate comparable to the vibration frequency. PROSE was able to produce smooth and accurate shear wave images from three homogeneous phantoms with different moduli, with an effective frame rate of 300Hz. An inclusion phantom study showed that increased vibration frequencies improved the accuracy of inclusion imaging, and allowed targets as small as 6.5 mm to be resolved with good contrast (contrast-to-noise ratio ≥19 dB) between the target and background.",
keywords = "Mechanical vibration, shear wave, ultrasound elastography",
author = "Mellema, {Daniel C.} and Pengfei Song and Armando Manduca and Urban, {Matthew W} and Kinnick, {Randall R.} and Greenleaf, {James F} and Chen, {Shigao D}",
year = "2015",
month = "11",
day = "13",
doi = "10.1109/ULTSYM.2015.0203",
language = "English (US)",
isbn = "9781479981823",
booktitle = "2015 IEEE International Ultrasonics Symposium, IUS 2015",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - A high frame-rate and low-cost Elastography system by generating shear waves through continuous vibration of the ultrasound transducer

AU - Mellema, Daniel C.

AU - Song, Pengfei

AU - Manduca, Armando

AU - Urban, Matthew W

AU - Kinnick, Randall R.

AU - Greenleaf, James F

AU - Chen, Shigao D

PY - 2015/11/13

Y1 - 2015/11/13

N2 - Ultrasound shear wave elastography (SWE) utilizes the propagation of induced shear waves to characterize the shear modulus of soft tissue. Many methods rely on an acoustic radiation force (ARF) push beam to generate shear waves. However, specialized hardware is required to generate the push beams, and the thermal stress that is placed upon the ultrasound system, transducer, and tissue by the push beams currently limits the frame-rate to about 1 Hz. This paper presents Probe Oscillation Shear Elastography (PROSE) as an alternative method to measure tissue elasticity, by generating shear waves using a continuous mechanical vibration of an ultrasound transducer, while simultaneously detecting motion with the same transducer under pulse-echo mode. Motion of the transducer during detection produces a compression strain artifact that is coupled with the observed shear waves. A novel symmetric sampling scheme is proposed such that pulse-echo detection events are acquired when the ultrasound transducer returns to the same physical position, allowing the shear waves to be decoupled from the compression artifact. Full field-of-view (FOV) two-dimensional (2D) shear wave speed (SWS) images were obtained by applying a local frequency estimation (LFE) method, capable of generating a 2D map from a single frame of shear wave motion, allowing for an imaging frame rate comparable to the vibration frequency. PROSE was able to produce smooth and accurate shear wave images from three homogeneous phantoms with different moduli, with an effective frame rate of 300Hz. An inclusion phantom study showed that increased vibration frequencies improved the accuracy of inclusion imaging, and allowed targets as small as 6.5 mm to be resolved with good contrast (contrast-to-noise ratio ≥19 dB) between the target and background.

AB - Ultrasound shear wave elastography (SWE) utilizes the propagation of induced shear waves to characterize the shear modulus of soft tissue. Many methods rely on an acoustic radiation force (ARF) push beam to generate shear waves. However, specialized hardware is required to generate the push beams, and the thermal stress that is placed upon the ultrasound system, transducer, and tissue by the push beams currently limits the frame-rate to about 1 Hz. This paper presents Probe Oscillation Shear Elastography (PROSE) as an alternative method to measure tissue elasticity, by generating shear waves using a continuous mechanical vibration of an ultrasound transducer, while simultaneously detecting motion with the same transducer under pulse-echo mode. Motion of the transducer during detection produces a compression strain artifact that is coupled with the observed shear waves. A novel symmetric sampling scheme is proposed such that pulse-echo detection events are acquired when the ultrasound transducer returns to the same physical position, allowing the shear waves to be decoupled from the compression artifact. Full field-of-view (FOV) two-dimensional (2D) shear wave speed (SWS) images were obtained by applying a local frequency estimation (LFE) method, capable of generating a 2D map from a single frame of shear wave motion, allowing for an imaging frame rate comparable to the vibration frequency. PROSE was able to produce smooth and accurate shear wave images from three homogeneous phantoms with different moduli, with an effective frame rate of 300Hz. An inclusion phantom study showed that increased vibration frequencies improved the accuracy of inclusion imaging, and allowed targets as small as 6.5 mm to be resolved with good contrast (contrast-to-noise ratio ≥19 dB) between the target and background.

KW - Mechanical vibration

KW - shear wave

KW - ultrasound elastography

UR - http://www.scopus.com/inward/record.url?scp=84962023054&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84962023054&partnerID=8YFLogxK

U2 - 10.1109/ULTSYM.2015.0203

DO - 10.1109/ULTSYM.2015.0203

M3 - Conference contribution

AN - SCOPUS:84962023054

SN - 9781479981823

BT - 2015 IEEE International Ultrasonics Symposium, IUS 2015

PB - Institute of Electrical and Electronics Engineers Inc.

ER -