3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain

Research output: Contribution to journalArticle

79 Citations (Scopus)

Abstract

Sensitivity encoding (SENSE) and partial Fourier techniques have been shown to reduce the acquisition time and provide high diagnostic quality images. However, for time-resolved acquisitions there is a need for both high temporal and spatial resolution. View sharing can be used to provide an increased frame rate but at the cost of acquiring spatial frequencies over a duration longer than a frame time. In this work we hypothesize that a CArtesian Projection Reconstruction-like (CAPR) technique in combination with 2D SENSE, partial Fourier, and view sharing can provide 1-2 mm isotropic resolution with sufficient temporal resolution to distinguish intracranial arterial and venous phases of contrast passage in whole-brain angiography. In doing so, the parameter of "temporal footprint" is introduced as a descriptor for characterizing and comparing time-resolved view-shared pulse sequences. It is further hypothesized that short temporal footprint sequences have higher temporal fidelity than similar sequences with longer temporal footprints. The tradeoff of temporal footprint and temporal acceleration is presented and characterized in numerical simulations. Results from 11 whole-brain contrast-enhanced MR angiography studies with the new method with SENSE acceleration factors R = 4 and 5.3 are shown to provide images of comparable or higher diagnostic quality than the unaccelerated reference.

Original languageEnglish (US)
Pages (from-to)749-760
Number of pages12
JournalMagnetic Resonance in Medicine
Volume60
Issue number3
DOIs
StatePublished - Sep 2008

Fingerprint

Angiography
Brain
R Factors

Keywords

  • 2D-partial Fourier
  • 2D-SENSE
  • Contrast-enhanced MR angiography
  • Temporal footprint
  • View sharing

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

@article{22201dd68618482f9dee0263d4bedfb4,
title = "3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain",
abstract = "Sensitivity encoding (SENSE) and partial Fourier techniques have been shown to reduce the acquisition time and provide high diagnostic quality images. However, for time-resolved acquisitions there is a need for both high temporal and spatial resolution. View sharing can be used to provide an increased frame rate but at the cost of acquiring spatial frequencies over a duration longer than a frame time. In this work we hypothesize that a CArtesian Projection Reconstruction-like (CAPR) technique in combination with 2D SENSE, partial Fourier, and view sharing can provide 1-2 mm isotropic resolution with sufficient temporal resolution to distinguish intracranial arterial and venous phases of contrast passage in whole-brain angiography. In doing so, the parameter of {"}temporal footprint{"} is introduced as a descriptor for characterizing and comparing time-resolved view-shared pulse sequences. It is further hypothesized that short temporal footprint sequences have higher temporal fidelity than similar sequences with longer temporal footprints. The tradeoff of temporal footprint and temporal acceleration is presented and characterized in numerical simulations. Results from 11 whole-brain contrast-enhanced MR angiography studies with the new method with SENSE acceleration factors R = 4 and 5.3 are shown to provide images of comparable or higher diagnostic quality than the unaccelerated reference.",
keywords = "2D-partial Fourier, 2D-SENSE, Contrast-enhanced MR angiography, Temporal footprint, View sharing",
author = "Haider, {Clifton R} and Hu, {Houchun Harry} and Campeau, {Norbert G} and Huston, {John III} and Riederer, {Stephen J}",
year = "2008",
month = "9",
doi = "10.1002/mrm.21675",
language = "English (US)",
volume = "60",
pages = "749--760",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - 3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain

AU - Haider, Clifton R

AU - Hu, Houchun Harry

AU - Campeau, Norbert G

AU - Huston, John III

AU - Riederer, Stephen J

PY - 2008/9

Y1 - 2008/9

N2 - Sensitivity encoding (SENSE) and partial Fourier techniques have been shown to reduce the acquisition time and provide high diagnostic quality images. However, for time-resolved acquisitions there is a need for both high temporal and spatial resolution. View sharing can be used to provide an increased frame rate but at the cost of acquiring spatial frequencies over a duration longer than a frame time. In this work we hypothesize that a CArtesian Projection Reconstruction-like (CAPR) technique in combination with 2D SENSE, partial Fourier, and view sharing can provide 1-2 mm isotropic resolution with sufficient temporal resolution to distinguish intracranial arterial and venous phases of contrast passage in whole-brain angiography. In doing so, the parameter of "temporal footprint" is introduced as a descriptor for characterizing and comparing time-resolved view-shared pulse sequences. It is further hypothesized that short temporal footprint sequences have higher temporal fidelity than similar sequences with longer temporal footprints. The tradeoff of temporal footprint and temporal acceleration is presented and characterized in numerical simulations. Results from 11 whole-brain contrast-enhanced MR angiography studies with the new method with SENSE acceleration factors R = 4 and 5.3 are shown to provide images of comparable or higher diagnostic quality than the unaccelerated reference.

AB - Sensitivity encoding (SENSE) and partial Fourier techniques have been shown to reduce the acquisition time and provide high diagnostic quality images. However, for time-resolved acquisitions there is a need for both high temporal and spatial resolution. View sharing can be used to provide an increased frame rate but at the cost of acquiring spatial frequencies over a duration longer than a frame time. In this work we hypothesize that a CArtesian Projection Reconstruction-like (CAPR) technique in combination with 2D SENSE, partial Fourier, and view sharing can provide 1-2 mm isotropic resolution with sufficient temporal resolution to distinguish intracranial arterial and venous phases of contrast passage in whole-brain angiography. In doing so, the parameter of "temporal footprint" is introduced as a descriptor for characterizing and comparing time-resolved view-shared pulse sequences. It is further hypothesized that short temporal footprint sequences have higher temporal fidelity than similar sequences with longer temporal footprints. The tradeoff of temporal footprint and temporal acceleration is presented and characterized in numerical simulations. Results from 11 whole-brain contrast-enhanced MR angiography studies with the new method with SENSE acceleration factors R = 4 and 5.3 are shown to provide images of comparable or higher diagnostic quality than the unaccelerated reference.

KW - 2D-partial Fourier

KW - 2D-SENSE

KW - Contrast-enhanced MR angiography

KW - Temporal footprint

KW - View sharing

UR - http://www.scopus.com/inward/record.url?scp=51449092401&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=51449092401&partnerID=8YFLogxK

U2 - 10.1002/mrm.21675

DO - 10.1002/mrm.21675

M3 - Article

C2 - 18727101

AN - SCOPUS:51449092401

VL - 60

SP - 749

EP - 760

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 3

ER -