• 18505 Citations
  • 72 Scopus h-Index
1989 …2019
If you made any changes in Pure, your changes will be visible here soon.

Research Output 1989 2019

2019
1 Citation (Scopus)

Ability of dual-energy CT to detect silicone gel breast implant rupture and nodal silicone spread

Glazebrook, K. N., Doerge, S., Leng, S., Drees, T. A., Hunt, K. N., Zingula, S. N., Pruthi, S., Geske, J. R., Carter, R. E., McCollough, C. H. & Fletcher, J. G., Apr 1 2019, In : American Journal of Roentgenology. 212, 4, p. 933-942 10 p.

Research output: Contribution to journalArticle

Silicone Gels
Breast Implants
Silicones
Rupture
Breast
2 Citations (Scopus)

A deep learning- and partial least square regression-based model observer for a low-contrast lesion detection task in CT

Gong, H., Yu, L., Leng, S., Dilger, S. K., Ren, L., Zhou, W., Fletcher, J. G. & McCollough, C. H., Jan 1 2019, In : Medical physics.

Research output: Contribution to journalArticle

Least-Squares Analysis
Learning
Noise
Liver
Radiation

Clinical assessment of metal artifact reduction methods in dual-energy CT examinations of instrumented spines

Long, Z., De Lone, D. R., Kotsenas, A. L., Lehman, V. T., Nagelschneider, A. A., Michalak, G. J., Fletcher, J. G., McCollough, C. H. & Yu, L., Feb 1 2019, In : American Journal of Roentgenology. 212, 2, p. 395-401 7 p.

Research output: Contribution to journalArticle

Artifacts
Spine
Metals
Bone and Bones

Clinical utility of virtual noncalcium dual-energy CT in imaging of the pelvis and hip

Baffour, F. I., Glazebrook, K. N., Morris, J. M., Michalak, G. J., Fletcher, J. G., Leng, S. & McCollough, C. H., Jan 1 2019, In : Skeletal Radiology.

Research output: Contribution to journalReview article

Pelvis
Hip
Bone Marrow
Pathology
Edema

Comparison of glenohumeral joint kinematics between manual wheelchair tasks and implications on the subacromial space: A biplane fluoroscopy study

Mozingo, J. D., Akbari-Shandiz, M., Van Straaten, M. G., Murthy, N. S., Schueler, B. A., Holmes, D. R., McCollough, C. H. & Zhao, K. D., Jan 1 2019, (Accepted/In press) In : Journal of Electromyography and Kinesiology. 102350.

Research output: Contribution to journalArticle

Shoulder Joint
Wheelchairs
Fluoroscopy
Biomechanical Phenomena
Humeral Head

Computed Tomography Cholangiography Using the Magnetic Resonance Contrast Agent Gadoxetate Disodium: A Phantom Study

Dilger, S. K. N., Nelson, N., Venkatesh, S. K., Ehman, E., Fidler, J. L., Fletcher, J. G., McCollough, C. H. & Yu, L., Sep 1 2019, In : Investigative radiology. 54, 9, p. 572-579 8 p.

Research output: Contribution to journalArticle

Cholangiography
Contrast Media
Noise
Magnetic Resonance Spectroscopy
Tomography
3 Citations (Scopus)

Computed Tomography Technology - And Dose - In the 21st Century

McCollough, C. H., Feb 1 2019, In : Health Physics. 116, 2, p. 157-162 6 p.

Research output: Contribution to journalArticle

Tomography
Technology
Photons
X-Rays
Noise

Correlation between a deep-learning-based model observer and human observer for a realistic lung nodule localization task in chest CT

Gong, H., Walther, A., Hu, Q., Koo, C. W., Takahashi, E. A., Levin, D. L., Johnson, T. F., Hora, M. J., Leng, S., Fletcher, J. G., McCollough, C. H. & Yu, L., Jan 1 2019, Medical Imaging 2019: Image Perception, Observer Performance, and Technology Assessment. Nishikawa, R. M. & Samuelson, F. W. (eds.). SPIE, 109520K. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10952).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

chest
nodules
lungs
learning
Thorax

Demonstration of phase-assisted material decomposition with a Talbot-Lau interferometer using a single x-ray tube potential

Shanblatt, E. R., Nelson, B. J., Tao, S., Leng, S. & McCollough, C. H., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109482W. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

x ray tubes
fats
Interferometers
Demonstrations
interferometers

Determination of iodine detectability in different types of multiple-energy images for a photon-counting detector computed tomography system

Zhou, W., Michalak, G., Weaver, J., Ferrero, A., Gong, H., Fetterly, K. A., McCollough, C. H. & Leng, S., Oct 1 2019, In : Journal of Medical Imaging. 6, 4, 043501.

Research output: Contribution to journalArticle

Photons
Iodine
Tomography
Area Under Curve
Noise
1 Citation (Scopus)
Cryosurgery
Ice
Pelvis
Spine
Tomography
1 Citation (Scopus)

Dual-source photon counting detector CT with a tin filter: a phantom study on iodine quantification performance

Tao, A., Huang, R., Tao, S., Michalak, G. J., McCollough, C. H. & Leng, S., May 31 2019, In : Physics in medicine and biology. 64, 11, 1 p.

Research output: Contribution to journalArticle

Tin
Photons
Iodine
Research Design
Least-Squares Analysis
1 Citation (Scopus)
Photons
Gadolinium
Bismuth
Noise
Head
1 Citation (Scopus)

Findings of CT-Derived Bone Strength Assessment in Inflammatory Bowel Disease Patients Undergoing CT Enterography in Clinical Practice

Maldonado, F. J., Al Bawardy, B. F., Nehra, A. K., Lee, Y. S., Bruining, D. H., Adkins, M. C., Keaveny, T. M., Johnson, M. P., Fidler, J. L., McCollough, C. H. & Fletcher, J. G., May 4 2019, In : Inflammatory bowel diseases. 25, 6, p. 1072-1079 8 p.

Research output: Contribution to journalArticle

Inflammatory Bowel Diseases
Bone and Bones
Metabolic Bone Diseases
Guidelines
Bone Density

Forward model for propagation-based X-ray phase contrast imaging in parallel- and conebeam geometry

Shanblatt, E. R., Sung, Y., Gupta, R., Nelson, B. J., Leng, S., Graves, W. S. & McCollough, C. H., Jan 1 2019, In : Optics Express. 27, 4, p. 4504-4521 18 p.

Research output: Contribution to journalArticle

phase contrast
propagation
geometry
x rays
cones
2 Citations (Scopus)

High-Resolution Chest Computed Tomography Imaging of the Lungs: Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography

Bartlett, D. J., Koo, C. W., Bartholmai, B. J., Rajendran, K., Weaver, J. M., Halaweish, A. F., Leng, S., McCollough, C. H. & Fletcher, J. G., Mar 1 2019, In : Investigative Radiology. 54, 3, p. 129-137 9 p.

Research output: Contribution to journalArticle

Photons
Bronchi
Thorax
Tomography
Lung
2 Citations (Scopus)

Impact of prior information on material decomposition in dual- and multienergy computed tomography

Ren, L., Tao, S., Rajendran, K., McCollough, C. H. & Yu, L., Jan 1 2019, In : Journal of Medical Imaging. 6, 1, 013503.

Research output: Contribution to journalArticle

Tomography
Iodine
Noise
Water
Gadolinium
Iodine
Noise
Photons
X-Rays
Whole-Body Counting

Individualized Delay for Abdominal Computed Tomography Angiography Bolus-Tracking Based on Sequential Monitoring: Increased Aortic Contrast Permits Decreased Injection Rate and Lower Iodine Dose

Gutjahr, R., Fletcher, J. G., Lee, Y. S., Halaweish, A. F., Suresh, V., Weber, N. M., Vrtiska, T. J., Williamson, E. E., Schmidt, B. & McCollough, C. H., Jul 1 2019, In : Journal of computer assisted tomography. 43, 4, p. 612-618 7 p.

Research output: Contribution to journalArticle

Licensure
Iodine
Injections
Tomography
Software
1 Citation (Scopus)

Lead shielding in pediatric chest CT: Effect of apron placement outside the scan volume on radiation dose reduction

Yu, L., Bruesewitz, M. R., Vrieze, T. J. & McCollough, C. H., Jan 1 2019, In : American Journal of Roentgenology. 212, 1, p. 151-156 6 p.

Research output: Contribution to journalArticle

Thorax
Radiation
Pediatrics
Pelvis
Abdomen
Theoretical Models
Liver
Water
Task Performance and Analysis
ROC Curve
1 Citation (Scopus)
Liver
Water
Noise
Computer-Assisted Image Processing
ROC Curve

Material decomposition in photon-counting-detector CT: Threshold or bin images?

Ren, L., Tao, S., McCollough, C. H. & Yu, L., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109482S. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Bins
Least-Squares Analysis
Photons
counting
Detectors

Multi-contrast imaging on dual-source photon-counting-detector (PCD) CT

Tao, S., Rajendran, K., McCollough, C. H. & Leng, S., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109484L. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Photons
Light sources
counting
Detectors
Imaging techniques

Multi-energy CT with triple x-ray beams and photon-counting-detector CT for simultaneous imaging of two contrast agents: An experimental comparison

Ren, L., McCollough, C. H. & Yu, L., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109481B. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Photons
Iodine
Contrast Media
counting
Bismuth
1 Citation (Scopus)

Optimal acquisition setting for dual-contrast imaging with gadolinium and iodine on a research whole-body photon-counting-detector (PCD) CT

Tao, S., Wu, Y., Rajendran, K., McCollough, C. H. & Leng, S., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109484I. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Whole-Body Counting
Gadolinium
gadolinium
Iodine
Photons
1 Citation (Scopus)

Photon-counting detector CT: System design and clinical applications of an emerging technology

Leng, S., Bruesewitz, M., Tao, S., Rajendran, K., Halaweish, A. F., Campeau, N. G., Fletcher, J. G. & McCollough, C. H., May 1 2019, In : Radiographics. 39, 3, p. 729-743 15 p.

Research output: Contribution to journalArticle

Photons
Technology
Contrast Media
Artifacts
Noise

Prior iterative reconstruction (PIR) to lower radiation dose and preserve radiologist performance for multiphase liver CT: a multi-reader pilot study

Mohammadinejad, P., Ehman, E. C., Vasconcelos, R. N., Venkatesh, S. K., Hough, D. M., Lowe, R., Lee, Y. S., Nehra, A., Dirks, S., Holmes, D. R., Carter, R. E., Schmidt, B., Halaweish, A. F., McCollough, C. H. & Fletcher, J. G., Jan 1 2019, (Accepted/In press) In : Abdominal Radiology.

Research output: Contribution to journalArticle

Computer-Assisted Image Processing
Radiation
Liver
Noise
Neoplasms
1 Citation (Scopus)

Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study

Ren, L., Rajendran, K., McCollough, C. H. & Yu, L., Jan 1 2019, (Accepted/In press) In : Medical physics.

Research output: Contribution to journalArticle

Tomography
Iodine
Gadolinium
Contrast Media
Bismuth

Quantitative cartilage imaging using spectral photon-counting detector based computed tomography

Rajendran, K., Tao, S., Benike, A., Leng, S. & McCollough, C. H., Jan 1 2019, Medical Imaging 2019: Biomedical Applications in Molecular, Structural, and Functional Imaging. Gimi, B. & Krol, A. (eds.). SPIE, 109531A. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10953).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

cartilage
Cartilage
Glycosaminoglycans
Photons
Tomography
1 Citation (Scopus)

Radiation dose efficiency of multi-energy photon-counting-detector CT for dual-contrast imaging

Ren, L., Rajendran, K., McCollough, C. H. & Yu, L., Dec 13 2019, In : Physics in medicine and biology. 64, 24, 1 p.

Research output: Contribution to journalArticle

Photons
Iodine
Radiation
Bismuth
Gadolinium

Reducing radiation dose for multi-phase contrast-enhanced dual energy renal CT: pilot study evaluating prior iterative reconstruction

Navin, P. J., Kim, B., Wells, M., Khandelwal, A., Halaweish, A. F., Moen, T. R., Johnson, M. P., McCollough, S., Lee, Y. S., Leng, S., McCollough, C. H. & Fletcher, J. G., Jan 1 2019, (Accepted/In press) In : Abdominal Radiology.

Research output: Contribution to journalArticle

Radiation
Kidney
Computer-Assisted Image Processing
Neoplasms
Kidney Neoplasms
3 Citations (Scopus)

Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration

Zhou, W., Bartlett, D. J., Diehn, F. E., Glazebrook, K. N., Kotsenas, A. L., Carter, R. E., Fletcher, J. G., McCollough, C. H. & Leng, S., Apr 1 2019, In : Investigative radiology. 54, 4, p. 204-211 8 p.

Research output: Contribution to journalArticle

Tin
Photons
Artifacts
Metals
Tomography
1 Citation (Scopus)

Renal Adiposity Does not Preclude Quantitative Assessment of Renal Function Using Dual-Energy Multidetector CT in Mildly Obese Human Subjects

Ferguson, C. M., Eirin, A., Michalak, G. J., Hedayat, F., Abumoawad, A. M., Hedayat, A. F., Zhu, X., Textor, S. C., McCollough, C. H. & Lerman, L. O., Jan 1 2019, (Accepted/In press) In : Academic Radiology.

Research output: Contribution to journalArticle

Adiposity
Kidney
Multidetector Computed Tomography
Iodine
Aorta
1 Citation (Scopus)

Simulation of CT images reconstructed with different kernels using a convolutional neural network and its implications for efficient CT workflow

Missert, A. D., Leng, S., McCollough, C. H., Fletcher, J. G. & Yu, L., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109482Y. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Workflow
Tomography
tomography
X-Ray Computed Tomography Scanners
Neural networks

State of the art in abdominal CT: The limits of iterative reconstruction algorithms

Mileto, A., Guimaraes, L. S., McCollough, C. H., Fletcher, J. G. & Yu, L., Jan 1 2019, In : Radiology. 293, 3, p. 491-503 13 p.

Research output: Contribution to journalArticle

Radiation
Noise
Neoplasm Metastasis
Technology
Liver
1 Citation (Scopus)
Kidney Calculi
Cohort Studies
Prospective Studies
Recurrence
Self Report

Technical Note: Increased photon starvation artifacts at low helical pitch in ultra-low-dose CT

Browne, J. E., Bruesewitz, M. R., Vrieze, T. J., McCollough, C. H. & Yu, L., Jan 1 2019, (Accepted/In press) In : Medical physics.

Research output: Contribution to journalArticle

Starvation
Photons
Artifacts
Delivery of Health Care
Noise
1 Citation (Scopus)

Understanding, justifying, and optimizing radiation exposure for CT imaging in nephrourology

Ferrero, A., Takahashi, N. M., Vrtiska, T. J., Krambeck, A. E., Lieske, J. C. & McCollough, C. H., Jan 1 2019, In : Nature Reviews Urology.

Research output: Contribution to journalReview article

Radiation
Diagnostic Imaging
Ionizing Radiation
Neoplasms
Urinary Calculi

Visibility guided phase contrast denoising

Nelson, B., Koenig, T., Shanblatt, E., Leng, S. & McCollough, C. H., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109484V. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Interferometry
phase contrast
visibility
Visibility
low visibility
2018
15 Citations (Scopus)

150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images

Leng, S., Rajendran, K., Gong, H., Zhou, W., Halaweish, A. F., Henning, A., Kappler, S., Baer, M., Fletcher, J. G. & McCollough, C. H., Nov 1 2018, In : Investigative Radiology. 53, 11, p. 655-662 8 p.

Research output: Contribution to journalArticle

Photons
Tomography
Technology
Noise
Research Ethics Committees
1 Citation (Scopus)

Breathe New Life Into Your Chest CT Exams: Using Advanced Acquisition and Postprocessing Techniques

Weber, N. M., Koo, C. W., Yu, L., Bartholmai, B. J., Halaweish, A. F., McCollough, C. H. & Fletcher, J. G., Jan 1 2018, (Accepted/In press) In : Current Problems in Diagnostic Radiology.

Research output: Contribution to journalArticle

Thorax
Tomography
Artifacts
Lung Diseases
X-Rays
3 Citations (Scopus)

Characterization of Urinary Stone Composition by Use of Whole-body, Photon-counting Detector CT

Ferrero, A., Gutjahr, R., Halaweish, A. F., Leng, S. & McCollough, C. H., Jan 1 2018, (Accepted/In press) In : Academic Radiology.

Research output: Contribution to journalArticle

Whole-Body Counting
Urinary Calculi
Photons
Tomography
ROC Curve
3 Citations (Scopus)

Comparison of a photon-counting-detector CT with an energy-integrating-detector CT for temporal bone imaging: A cadaveric study

Zhou, W., Lane, J. I., Carlson, M. L., Bruesewitz, M. R., Witte, R. J., Koeller, K. K., Eckel, L. J., Carter, R. E., McCollough, C. H. & Leng, S., Sep 1 2018, In : American Journal of Neuroradiology. 39, 9, p. 1733-1738 6 p.

Research output: Contribution to journalArticle

Temporal Bone
Photons
Stapes
Comb and Wattles
Anatomy
1 Citation (Scopus)

Correlation between model observers in uniform background and human observers in patient liver background for a low-contrast detection task in CT

Gong, H., Yu, L., Leng, S., DIlger, S., Zhou, W., Ren, L. & McCollough, C. H., Jan 1 2018, Medical Imaging 2018: Image Perception, Observer Performance, and Technology Assessment. SPIE, Vol. 10577. 105770M

Research output: Chapter in Book/Report/Conference proceedingConference contribution

liver
Liver
lesions
Computerized tomography
Image quality
5 Citations (Scopus)

Detection and characterization of renal stones by using photon-counting-based CT

Marcus, R. P., Fletcher, J. G., Ferrero, A., Leng, S., Halaweish, A. F., Gutjahr, R., Vrtiska, T. J., Wells, M., Enders, F. T. & McCollough, C. H., Nov 1 2018, In : Radiology. 289, 2, p. 436-442 7 p.

Research output: Contribution to journalArticle

Photons
Kidney
Cone-Beam Computed Tomography
Uric Acid
Research
2 Citations (Scopus)

Determination of optimal image type and lowest detectable concentration for iodine detection on a photon counting detector-based multi-energy CT system

Zhou, W., Schornak, R., Michalak, G., Weaver, J., Abdurakhimova, D., Ferrero, A., Fetterly, K. A., McCollough, C. H. & Leng, S., Jan 1 2018, Medical Imaging 2018: Physics of Medical Imaging. SPIE, Vol. 10573. 105734U

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Iodine
Photons
iodine
low concentrations
counting
8 Citations (Scopus)

Dual-source multienergy CT with triple or quadruple x-ray beams

Yu, L., Ren, L., Li, Z., Leng, S. & McCollough, C. H., Jul 1 2018, In : Journal of Medical Imaging. 5, 3, 033502.

Research output: Contribution to journalArticle

Photons
X-Rays
Contrast Media
Computer Simulation
Noise